Analysis of post-exposure density growth in radiochromic film with respect to the radiation dose.

نویسندگان

  • Katsumi Shima
  • Kunihiko Tateoka
  • Yuichi Saitoh
  • Junji Suzuki
  • Yuji Yaegashi
  • Kazunori Fujimoto
  • Takuya Nakazawa
  • Akihiro Nakata
  • Tadanori Abe
  • Sho Imai
  • Kouichi Sakata
  • Masato Hareyama
چکیده

The post-exposure density growth (PEDG) is one of the characteristics of radiochromic film (RCF). In film dosimetry using RCF and a flatbed scanner, pixel values read out from the RCF are converted to dose (hereafter, film dose) by using a calibration curve. The aim of this study is to analyze the relationship between the pixel value read out from the RCF and the PEDG, and that between the film dose converted from the RCF and the PEDG. The film (GAFCHROMIC EBT) was irradiated with 10-MV X-rays in an ascending 11-dose-step arrangement. The pixel values of the irradiated EBT film were measured at arbitrary hours using an Epson flatbed scanner. In this study, the reference time was 24 h after irradiation, and all dose conversions from the pixel values read out from the EBT film were made using a calibration curve for 24 h after irradiation. For delivered doses of 33 and 348 cGy, the measured pixel values at 0.1 and 16 h after irradiation represented ranges of -9.6% to -0.7% and -3.9% to -0.3%, respectively, of the reference value. The relative changes between the pixel values read out from the EBT film at each elapsed time and that at the reference time decreased with increasing delivered dose. However, the difference range for all the film doses had a width of approximately -10% of the reference value at elapsed times from 0.1 to 16 h, and it showed no dependence on the delivered dose.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Post-irradiation colouration of Gafchromic EBT radiochromic film.

Gafchromic EBT (International Specialty Products, NJ, USA), radiochromic film is one of the newest radiation-induced auto-developing x-ray analysis films available for therapeutic radiation dosimetry in radiotherapy applications. Part of any radiochromic film product which undergoes a polymerization reaction for automatic darkening is an associated post-irradiation colouration whereby the film ...

متن کامل

Dosimetric comparison between XR-RV3 and EBT2 radiochromic film in megavoltage photon beams

Background:  Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

متن کامل

Skin Dosimetry in Radiotherapy of Breast Cancer: a Comparison between EBT and EBT3 Radiochromic Films

Objective: Radiochromic EBT3 film is a later generation of radiochromic films. The aim of this study is to compare EBT and EBT3 radiochromic films in radiotherapy fields of breast cancer.Methods: A RANDO phantom was irradiated by a 6 MV Siemens Primus linac with medial and lateral fields of radiotherapy of breast cancer. Dosimetry was performed in various points in the fields using EBT and EBT3...

متن کامل

Enhancement of MD-55-2 radiochromic film sensitivity using a multilayer film technique for applications in the low dose range

 ABSTRACTBackgrounds: MD-55-2 is one of the Radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 Gy.  However, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.Materials and methods: In this project, the useful range of the film has been extended by using a multilayer film techniqu...

متن کامل

Comparison of EBT and EBT3 RadioChromic Film Usage in Parotid Cancer Radiotherapy

Background: EBT and EBT3 radioChromic films have been used in radiotherapy dosimetry for years.Objective: The aim of the current study is to compare EBT and EBT3 radioChromic films in dosimetry of radiotherapy fields for treatment of parotid cancer.Methods: Calibrations of EBT and EBT3 films were performed with identical setups using a 6 MV photon beam of a Siemens Primus linac. Skin dose was m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiation research

دوره 53 2  شماره 

صفحات  -

تاریخ انتشار 2012