Interventional Removal of Intravascular Medical Devices: Methods and Technical Success Interventionelle Bergung intravasaler Fremdkörper: Methoden und technischer Erfolg
نویسندگان
چکیده
Correspondence Dr. Isabelle Ayx Radiologie, Barmherzige Brüder Regensburg Prüfeningerstraße 86 93049 Regensburg Germany Tel.: ++ 49/9 41/369943 72 Fax: ++ 49/9 41/3 692523 [email protected] Abstract ▼ Purpose: Evaluation of the technical success rate and complications when retrieving dislocated intravascular foreign bodies. Material and Methods: Between 1999 and 2015 38 patients (21 female; 17 male; Age: 17–92; Average 54.3 years) underwent an extraction of intravascular dislocated foreign bodies, which were not lost during a radiological intervention. The extracted material included 29 port catheters, 3 tips of tunneled dialysis catheters, 2 stents, 2 guide wires, 1 CVC tip and 1 AS occluder device. Various catheters for repositioning and extraction were used. The access was transarterial as well as transvenous. Technical success was defined as complete removal of the foreign body. Results: The technical success rate was 92.1% (35 of 38). In 17 patients an additional catheter was necessary to reposition the foreign body in order to make it accessible for the extraction catheter. In one case a stent was relocated and remodeled within the patient and was not extracted. In another case we experienced a dislocation of a small fragment of the port catheter into the distal parts of the pulmonary artery, which couldn’t be extracted. A guide wire could not be extracted as it was already adhered with the vessel wall. Peri-interventional complications were not documented. Conclusion: The percutaneous extraction of dislocated intravascular foreign bodies is technically successful and poor of complications. Interventional therapy can avoid surgical removal. Key points: ▶ The percutaneous extraction of dislocated intravascular foreign bodies is technically successful and safe. ▶ In most cases surgical removal can be avoided. ▶ The gooseneck-snare catheter was mainly used for the extraction of intravascular foreign bodies. Citation Format: ▶ Ayx I, Goessmann H, Hubauer H et al. Interventional Removal of Intravascular Medical Devices: Methods and Technical Success. Fortschr Röntgenstr 2016; 188: 566–573
منابع مشابه
Interventional Removal of Intravascular Medical Devices: Methods and Technical Success.
PURPOSE Evaluation of the technical success rate and complications when retrieving dislocated intravascular foreign bodies. MATERIAL AND METHODS Between 1999 and 2015 38 patients (21 female; 17 male; Age: 17 - 92; Average 54.3 years) underwent an extraction of intravascular dislocated foreign bodies, which were not lost during a radiological intervention. The extracted material included 29 po...
متن کاملQualitätsreport 2011: Bericht über die Behandlungsqualität minimalinvasiver Methoden – Teil 2 Interventionelle Therapie (EVAR) von Aortenaneurysmen Quality Report 2011 of the German Society of Interventional Radiology (DeGIR) – Part 2 Endovascular Treatment of Aortic Aneurysms (EVAR)
Ziel: Analyse der Behandlungsqualität der endovaskulären Versorgung von Aortenaneurysmen anhand der Eingaben in das DeGIR-Qualitätssicherungssystem. Material und Methoden: Die Daten des Jahres 2011 zur Behandlungsqualität der endovaskulären Versorgung von Aortenaneurysmen des freiwilligen DeGIR-Qualitätssicherungssystems wurden retrospektiv ausgewertet. Die Indikationsstellung, der Therapieproz...
متن کاملWhite Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 2: Liver and Other Applications in Oncology White Paper: Interventionelle MRT: Status Quo und Entwicklungspotenzial unter ökonomischen Perspektiven, Teil 2: Therapeutische und onkologische Anwendungen
Background MRI is attractive for guiding and monitoring interventional procedures due to its high intrinsic soft tissue contrast and the possibility to measure flow and cardiac function. Methods Technical solutions have been developed for all procedural steps including imaging guidance, MR-safe catheters and instruments and patient monitoring. This has led to widening of the clinical applicatio...
متن کاملNachhaltige Agile Transition: Symbiose von technischer und kultureller Agilität
Agile Entwicklungsvorgehen stellen den Stand der Technik bei der Entwicklung von Software und Systemen in unterschiedlichen Domänen dar. Beim Einsatz agiler Methoden wie Scrum kommt es jedoch häufiger zu Problemen, da die Einführung derartiger Methoden häufig nur aus technischer Sicht betrachtet wird. Die Berücksichtigung eines, als Voraussetzung für die nachhaltige Etablierung, kulturellen Wan...
متن کاملEinsatz formaler Methoden zur Evaluierung der Gebrauchsfähigkeit interaktiver Geräte (Utilization of Formal Methods for the Usability Evaluation of Interactive Devices)
Gebrauchsfähigkeit ist ein wichtiges Attribut interaktiver Systeme. Sie kann empirisch erst ermittelt werden, wenn ein funktionsfähiger Prototyp zur Verfügung steht. Da sich die Entwicklungsprozesse ständig beschleunigen, kommen empirische Ergebnisse jedoch häufig zu spät, um noch in den Entwicklungsprozess einfließen zu können. Dieser Beitrag beschreibt als Alternative den Einsatz formaler Bew...
متن کامل