Within-session and between-session variability of haemodialysis shunt flow measurements.

نویسندگان

  • Roel M Huisman
  • Marja van Dijk
  • Cor de Bruin
  • Jan Loonstra
  • Wim J Sluiter
  • Clark J Zeebregts
  • Jan J A M van den Dungen
چکیده

BACKGROUND Knowledge of the variability of a measurement method is essential for its clinical application. We investigated the variability of shunt flow measurements, since this is a relatively neglected area in the literature. In particular, no direct comparison of between-session and within-session variability was available until now. METHODS During two consecutive dialysis sessions, shunt flow was measured three times with the ultrasound dilution method in 24 chronic haemodialysis patients with various types of shunts. Needle orientation and blood pressure at the time of flow measurement were recorded. In these patients, shunt flow was also measured three times by duplex ultrasound before the first dialysis session. RESULTS The within-session variation coefficient (VC) of shunt flow measured with ultrasound dilution was 7.7%, whereas the between-session VC was 14.2% (n.s.). The within-session VC of Doppler shunt flow was 11.6% which was not significantly different from the corresponding figure of ultrasound dilution. Analysis of subgroups showed that changes in needle orientation caused large differences between sessions in radiocephalic fistulas but not in brachiocephalic fistulas: in the radiocephalic fistulas with the same needle orientation, VC was 6.7%, but with different needle orientation it was 23.5% (P = 0.02); the corresponding figures for brachiocephalic fistulas were 14.6% (same direction) and 11.4% (different direction, n.s.). CONCLUSION Reproducibility of shunt flow measurements between dialysis sessions in radiocephalic fistulas is critically dependent on similar needle orientation. With similar needle position and correction for blood pressure differences, flow changes of more than 20-25% are likely to reflect true flow changes. The variability of duplex flow measurements is at least as large as that of the ultrasound dilution method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new method of post-dialysis blood urea sampling: the 'stop dialysate flow' method.

BACKGROUND A standardized practical method of post-dialysis blood sampling is required to improve the precision of using urea kinetics in the evaluation of haemodialysis dose and to permit comparative audit. The methods recommended in the Renal Association and Dialysis Outcomes Quality Initiative (DOQI) guidelines reduce the blood pump speed to a low rate at the end of haemodialysis before bloo...

متن کامل

Do changes within a manual therapy treatment session predict between-session changes for patients with cervical spine pain?

Physiotherapists often use within-session changes to provide a guide for refining treatment application. This study tested the validity of within-session changes as predictors of between-session changes for patients with neck pain receiving manual therapy treatment. A total of 70 pairs of treatments from 29 patients with sub-acute non-specific neck pain receiving manual therapy were assessed to...

متن کامل

Inter Subject Variability and Reproducibility of Diffusion Tensor Imaging within and between Different Imaging Sessions

The aim of these studies was to provide reference data on intersubject variability and reproducibility of diffusion tensor imaging. Healthy volunteers underwent imaging on two occasions using the same 3T Siemens Verio magnetic resonance scanner. At each session two identical diffusion tensor sequences were obtained along with standard structural imaging. Fractional anisotropy, apparent diffusio...

متن کامل

Mapping Long-Term Functional Changes in Cerebral Blood Flow by Arterial Spin Labeling

Although arterial spin labeling (ASL) is appealing for mapping long-term changes in functional activity, inter-sessional variations in basal blood flow, arterial transit times (ATTs), and alignment errors, can result in significant false activation when comparing images from separate sessions. By taking steps to reduce these sources of noise, this study assessed the ability of ASL to detect fun...

متن کامل

Reliability of brain volume measurements: A test-retest dataset

Evaluation of neurodegenerative disease progression may be assisted by quantification of the volume of structures in the human brain using magnetic resonance imaging (MRI). Automated segmentation software has improved the feasibility of this approach, but often the reliability of measurements is uncertain. We have established a unique dataset to assess the repeatability of brain segmentation an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 20 12  شماره 

صفحات  -

تاریخ انتشار 2005