Differential phase-contrast microscope with a split detector for the readout system of a multilayered optical memory.
نویسندگان
چکیده
A transmission differential phase-contrast microscope with a split detector is used as a readout system for a multilayered three-dimensional optical memory. The system is applicable to data recorded as refractive-index changes. The system is compact and easy to use. The three-dimensional optical transfer function for the system is derived. This shows that the spatial bandwidth of the system is the same as that of a conventional microscope with incoherent illumination but with much improved contrast. Six layers of information are recorded in a photopolymer and are read out with little cross talk and high contrast.
منابع مشابه
Compact Fiber Laser and Fiber Readout System for Multilayered Optical Memory
We developed a compact and high-power modelocked fiber laser for multilayered optical memories. The average power and pulse width of the output pulse from the fiber laser that we developed were 109 mW and 2.1 ps, respectively. The dispersion of the output pulse was compensated with an external single-mode fiber of 2.5 m length. The pulse was compressed from 2.1 ps to 93 fs by dispersion compens...
متن کاملDesigning and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملRe-evaluation of differential phase contrast (DPC) in a scanning laser microscope using a split detector as an alternative to differential interference contrast (DIC) optics.
In this paper, differential phase imaging (DPC) with transmitted light is implemented by adding a suitable detection system to a standard commercially available scanning confocal microscope. DPC, a long-established method in scanning optical microscopy, depends on detecting the intensity difference between opposite halves or quadrants of a split photodiode detector placed in an aperture plane. ...
متن کاملPhase-randomized laser illumination for microscopy.
A simple apparatus is described that phase randomizes the output of a continuous argon ion laser, so that it may be used as a source of high intensity, monochromatic light for microscopy. The phase-randomizing device can be used with any laser, polarized or unpolarized, and of any desired power output and wavelength, including dye lasers for spectral studies. The randomizing system can be adapt...
متن کاملA Fast-readout CCD System for Configured-Detector Imaging in STXM
This paper describes a configured-detector imaging system based around an electron-multiplying CCD (iXon DV860 from Andor Technology) that combines fast frame-transfer readout with very high sensitivity. The detector consists of a Peltier-cooled CCD array of 128 by 128 sensors, and makes use of visible light coupling to a phosphor screen, to make it easy to operate over a wide range of photon e...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 35 14 شماره
صفحات -
تاریخ انتشار 1996