Correlation of single photon emission CT with MR image data using fiduciary markers.
نویسندگان
چکیده
PURPOSE To describe our approach to mapping the functional information provided by single photon emission computed tomography (SPECT) onto the anatomic template provided by MR, and to determine both the number of markers required to achieve accuracy and the impact of voxel shape on accuracy. METHODS Point-to-point iterative minimization using externally fixed fiducial markers was involved and computer simulations were performed. Two types of validation studies were performed using a phanton using a phantom of known dimensions. First, the spatial distortion that may be present in MR was investigated for spin-echo and gradient-recalled echo images. Next, the accuracy with which the SPECT image could be transformed to match the MR template was analyzed. The method is also demonstrated in four cases of patients with epilepsy. RESULTS Computer simulations indicated that for voxel dimensions we expected to use, eight fiduciary markers would consistently produce acceptable accuracy. Simulations also showed that more isotropic voxels would be more accurate if voxel volume is held constant. The spatial accuracy of both spin-echo and gradient-recalled echo images of a phantom was accurate to within 3 mm. When the SPECT image of the same phantom was correlated with the MR image using this technique, internal marker errors were never greater than 3 mm, and the mean error was 2.2 mm. CONCLUSIONS Images from different modalities can be accurately correlated using multiple fiduciary markers. SPECT and MR images of the given dimensions can be correlated to within 3 mm. The technique aids in clarification of the nature of SPECT perfusion abnormalities and in their anatomic localization.
منابع مشابه
Accuracy of coregistration of single-photon emission CT with MR via a brain surface matching technique.
We describe a technique of brain surface matching of single-photon emission CT and MR images in human subjects and document the accuracy of this technique with the use of fiduciary markers. This mismatch averaged 4.3 mm as measured by the fiduciary markers and 2.1 mm as measured by the root mean square distance.
متن کاملTriple-technique (MR imaging, single-photon emission CT, and CT) coregistration for image-guided surgical evaluation of patients with intractable epilepsy.
Ictal and interictal single-photon emission CT (SPECT) play an increasingly important role in the surgical evaluation of patients with epilepsy. We present a method of coregistration of MR, SPECT, and CT images to correlate structural data (MR imaging), blood flow changes (SPECT), and location of subdural electrodes (CT) for patients undergoing image-guided surgical treatment of epilepsy. MR-SP...
متن کاملImage Optimization in Single Photon Emission Computed Tomography by Hardware Modifications with Monte Carlo Simulation
Introduction: In Single Photon Emission Computed Tomography (SPECT), the projection data used for image reconstruction are distorted by several factors, including attenuation and scattering of gamma rays, collimator structure, data acquisition method, organ motion, and washout of radiopharmaceuticals. All these make reconstruction of a quantitative SPECT image very difficult. Simulation of a SP...
متن کاملGenerating the synthetic CT (sCT) and synthetic MR (sMR: sT1w/sT2w) images of the brain using atlas based method
Introduction: Radiation therapy planning (RTP) is one of the clinical applications in which both CT scan and MRI are used. MR and CT images are applied to determine the target volume and calculation of dose distribution, respectively. In addition, using two imaging modalities increases the department workload and cost. In this study, an algorithm was presented to create synthet...
متن کاملGenerating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method
Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 14 3 شماره
صفحات -
تاریخ انتشار 1993