Blind Structured Illumination Microscopy Reconstruction in Thick Samples
نویسندگان
چکیده
Aurélie Jost, Elen Tolstik, Bo-Jui Chang, Ernst H.K. Stelzer, Anne Sentenac and Rainer Heintzmann Institute of Physical Chemistry, Abbe Center of Photonics, Friedrich-SchillerUniversity Jena, Helmholtzweg 4, 07743 Jena, Germany Leibniz Institute of Photonic Technology, Albert-Einstein Str. 9, 07745 Jena, Germany BMLS, Physical Biology, Goethe University, D-60438 Frankfurt am Main, Germany Institut Fresnel, Campus de St Jérôme, 13013 Marseille, France King’s College London, Randall Division of Cell and Molecular Biophysics, London, United Kingdom E-mail: [email protected]
منابع مشابه
Optical Sectioning and High Resolution in Single-Slice Structured Illumination Microscopy by Thick Slice Blind-SIM Reconstruction
The microscope image of a thick fluorescent sample taken at a given focal plane is plagued by out-of-focus fluorescence and diffraction limited resolution. In this work, we show that a single slice of Structured Illumination Microscopy (two or three beam SIM) data can be processed to provide an image exhibiting tight sectioning and high transverse resolution. Our reconstruction algorithm is ada...
متن کاملMethods for imaging thick specimens: confocal microscopy, deconvolution, and structured illumination.
When a thick specimen is viewed through a conventional microscope, one sees the sum of a sharp image of an in-focus region plus blurred images of all of the out-of-focus regions. High background, scattering, and aberrations are all problems when viewing thick specimens. Several methods are available to deal with these problems in living samples. These methods can be grouped into three classes: ...
متن کاملTwo-photon excitation improves multifocal structured illumination microscopy in thick scattering tissue.
Multifocal structured illumination microscopy (MSIM) provides a twofold resolution enhancement beyond the diffraction limit at sample depths up to 50 µm, but scattered and out-of-focus light in thick samples degrades MSIM performance. Here we implement MSIM with a microlens array to enable efficient two-photon excitation. Two-photon MSIM gives resolution-doubled images with better sectioning an...
متن کاملOptimized approaches for optical sectioning and resolution enhancement in 2D structured illumination microscopy
The use of structured illumination in fluorescence microscopy allows the suppression of out of focus light and an increase in effective spatial resolution. In this paper we consider different approaches for reconstructing 2D structured illumination images in order to combine these two attributes, to allow fast, optically sectioned, superresolution imaging. We present a linear reconstruction met...
متن کاملResolution improvement in fluorescence and phase optical microscopy
Various fields of experimental science are constantly requiring smaller resolu-tion for optical microscopy. In this thesis are presented several works for im-proving resolution in fluorescence microscopy and in Tomographic DiffractionMicroscopy (TDM), an emerging phase microscopy technique. In the first partit is shown that one can improve the axial resolution in depositing ...