Reduced field-of-view diffusion imaging of the human spinal cord: comparison with conventional single-shot echo-planar imaging.

نویسندگان

  • G Zaharchuk
  • E U Saritas
  • J B Andre
  • C T Chin
  • J Rosenberg
  • T J Brosnan
  • A Shankaranarayan
  • D G Nishimura
  • N J Fischbein
چکیده

BACKGROUND AND PURPOSE DWI of the spinal cord is challenging because of its small size and artifacts associated with the most commonly used clinical imaging method, SS-EPI. We evaluated the performance of rFOV spinal cord DWI and compared it with the routine fFOV SS-EPI in a clinical population. MATERIALS AND METHODS Thirty-six clinical patients underwent 1.5T MR imaging examination that included rFOV SS-EPI DWI of the cervical spinal cord as well as 2 comparison diffusion sequences: fFOV SS-EPI DWI normalized for either image readout time (low-resolution fFOV) or spatial resolution (high-resolution fFOV). ADC maps were created and compared between the methods by using single-factor analysis of variance. Two neuroradiologists blinded to sequence type rated the 3 DWI methods, based on susceptibility artifacts, perceived spatial resolution, signal intensity-to-noise ratio, anatomic detail, and clinical utility. RESULTS ADC values for the rFOV and both fFOV sequences were not statistically different (rFOV: 1.01 ± 0.18 × 10(-3) mm(2)/s; low-resolution fFOV: 1.12 ± 0.22 × 10(-3) mm(2)/s; high-resolution fFOV: 1.10 ± 0.21 × 10(-3) mm(2)/s; F = 2.747, P > .05). The neuroradiologist reviewers rated the rFOV diffusion images superior in terms of all assessed measures (P < 0.0001). Particular improvements were noted in patients with metal hardware, degenerative disease, or both. CONCLUSIONS rFOV DWI of the spinal cord overcomes many of the problems associated with conventional fFOV SS-EPI and is feasible in a clinical population. From a clinical standpoint, images were deemed superior to those created by using standard fFOV methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DWI of the spinal cord with reduced FOV single-shot EPI.

Single-shot echo-planar imaging (ss-EPI) has not been used widely for diffusion-weighted imaging (DWI) of the spinal cord, because of the magnetic field inhomogeneities around the spine, the small cross-sectional size of the spinal cord, and the increased motion in that area due to breathing, swallowing, and cerebrospinal fluid (CSF) pulsation. These result in artifacts with the usually long re...

متن کامل

Diffusion tensor imaging in human cervical spondylotic myelopathy using a 2D RF excitation pulse combined with a reduced field-of-view single-shot echoplanar readout (Zoomed-EPI)

Introduction Cervical spondylotic myelopathy (CSM) is a spinal disorder characterized by degeneration of vertebral bodies, intervertebral disks, facet joints, and associated ligaments typically resulting in formation of bony spurs and myelopathy. CSM frequency increases with increasing age, where as many as 95% of men and 70% of women over age 60 to 65 have degenerative changes at one or more v...

متن کامل

Hadamard slice encoding for reduced-FOV diffusion-weighted imaging.

PURPOSE To improve the clinical utility of diffusion-weighted imaging (DWI) by extending the slice coverage of a high-resolution reduced field-of-view technique. THEORY Challenges in achieving high spatial resolution restrict the use of DWI in assessment of small structures such as the spinal cord. A reduced field-of-view method with 2D echo-planar radiofrequency (RF) excitation was recently ...

متن کامل

Diffusion tensor MR imaging of the neurologically intact human spinal cord.

BACKGROUND AND PURPOSE The aim of this study was to characterize the diffusion properties of the entire human spinal cord in vivo. These data are essential for comparisons to pathologic conditions as well as for comparisons of different pulse sequence design parameters aimed to reduce scan time and more accurately determine diffusion coefficients. MATERIALS AND METHODS A total of 13 neurologi...

متن کامل

Diffusion tensor MR imaging in chronic spinal cord injury.

BACKGROUND AND PURPOSE Diffusion tensor MR imaging is emerging as an important tool for displaying anatomic changes in the brain after injury or disease but has been less widely applied to disorders of the spinal cord. The aim of this study was to characterize the diffusion properties of the entire human spinal cord in vivo during the chronic stages of spinal cord injury (SCI). These data provi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 32 5  شماره 

صفحات  -

تاریخ انتشار 2011