A novel method for endoscopic placement of a capsule endoscope with use of a transparent hood and real-time viewer.

نویسندگان

  • Yuji Ino
  • Tomonori Yano
  • Hirotsugu Sakamoto
  • Yoshikazu Hayashi
  • Hiroyuki Osawa
  • Alan T Lefor
  • Hironori Yamamoto
چکیده

a capsule endoscope with use of a transparent hood and real-time viewer Capsule endoscopy relies on an intact swallowing mechanism and unimpeded passage of the capsule through the pylorus [1]. A new method for endoscopic placement of the capsule is described. A transparent hood (MH-464; Olympus, Tokyo, Japan), whose inside wall is lined with vinyl tape, is attached to the tip of the endoscope (●" Fig.1a). The activated capsule endoscope is monitored with a RAPID real-time viewer (Given Imaging, Yokne’am Illit, Israel). The capsule is placed inside the transparent hood, with the same tilt angles used for both the endoscopic image and the capsule endoscope image (●" Fig.1b). Because the capsule prevents visualization of the endoscopic image, the RAPID real-time viewer is used to watch the capsule endoscope image while the endoscope with the capsule is advanced through the pharynx, esophagus, and stomach into the duodenum (●" Fig.2). The capsule is then released into the duodenum by injecting water through the accessory channel (●" Fig.3). The procedure is shown in ●" Video 1. Six patients underwent successful endoscopic duodenal placement of the capsule without complications. In one case, biopsy forceps were needed to eject the capsule because the capsule was not released after water had been injected. A complete small-bowel examination was achieved in all six patients. Themean time required for the capsule to pass from the pharynx through the pyloruswas 5minutes. Therefore, our method is speedier and easier to use than previously reported methods [2–4]. Because the currently available capsule endoscope (PillCam SB 2; Given Imaging) provides two frames per second, the operator may be aware of a time lag between maneuvering the endoscope and viewing the capsule endoscope images. However, this will not occur when a newer version of the capsule endoscope with adaptive frame rate technology is used. The described method for endoscopic placement of the capsule endoscope in patients with dysphagia, anatomical abnormalities, or gastroparesis is safe and effective. Fig.1 a,b A novel method for endoscopic placement of a capsule endoscope. a A transparent hood, whose inside wall is lined with vinyl tape, is attached to the tip of the endoscope. b The capsule is placed inside the transparent hood, with the same tilt angles used for both the endoscopic image and the capsule endoscope image.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Video Capsule Retention in a Zenker Diverticulum

We report the case of a video capsule endoscope lodged within a Zenker diverticulum. The system that was equipped with a real-time viewer showed an unchanging image unlike esophageal or gastric mucosa, suggesting that the capsule was elsewhere. The presence of cervical discomfort suggested video capsule retention in a Zenker diverticulum. The capsule was removed endoscopically and reinserted us...

متن کامل

Overtube-assisted placement of a capsule endoscope in a patient with a swallowing disorder.

Small-bowel video capsule endoscopy (VCE) is generally contraindicated in patients with swallowing disorders. However, it is difficult to judge the ability of patients to swallow a capsule endoscope before examination and accidental aspiration of capsule endoscopes has been reported [1–3]. Previously, it was reported that overtube-assisted VCE placement was useful [4,5]. A 64-year-old man under...

متن کامل

A novel endoscopic technique for closure of a large esophageal perforation using the clip-and-snare method with the prelooping technique.

It is sometimes difficult to close a large perforation using endoclips and over-thescope clips, and surgery may be required [1]. We report a novel endoscopic technique for closure of a large perforation using the clip-and-snare method with the prelooping technique. A 76-year-old man with a metachronous esophageal cancer, which developed at a scar in the cervical esophagus that resulted from a p...

متن کامل

A New Endoscopic Technique for Examination of Esophageal Stenosis: The Funnel-shaped Transparent Cap Technique

We have devised a funnel-shaped transparent cap for the endoscopic diagnosis and treatment of stenosis in the digestive tract. This funnel-shaped cap is made of highly transparent methacrylic resin. A 73-year-old woman with reflux esophagitis (categorized as grade D by the Los Angeles Classification) visited our hospital with the chief complaint of dysphagia. She was examined using an endoscope...

متن کامل

A Computer Vision based Speed Estimation Technique for Localizing the Wireless Capsule Endoscope inside Small Intestine

Wireless Capsule Endoscope (WCE) provides a noninvasive way to inspect the entire small intestine. As a critical component of capsule endoscopic examination, physicians need to know the precise position of the endoscopic capsule in order to identify the position of intestinal disease after it is found by the video source. For the WCE, the position of the capsule is defined as the linear distanc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Endoscopy

دوره 47 Suppl 1 UCTN  شماره 

صفحات  -

تاریخ انتشار 2015