Scanners for Analytic Print Measurement – the devil in the details

نویسندگان

  • Eric K. Zeise
  • Don Williams
  • Peter D. Burns
  • William C. Kress
چکیده

Inexpensive and easy-to-use linear and area-array scanners have frequently substituted as colorimeters and densitometers for low-frequency (i.e., large area) hard copy image measurement. Increasingly, scanners are also being used for high spatial frequency, image microstructure measurements, which were previously reserved for high performance microdensitometers. In this paper we address characteristics of flatbed reflection scanners in the evaluation of print uniformity, geometric distortion, geometric repeatability and influence of scanner MTF and noise on analytic measurements. Suggestions are made for the specification and evaluation of scanners to be used in print image quality standards that are being developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of organ dose in abdomen-pelvis CT exam as a function of mA, KV and scanner type by Monte Carlo method .

Background: CT is a diagnostic imaging modality giving higher patient dose in comparison with other radiological procedures, so the calculation of organ dose in CT exams is very important. While methods to calculate the effective dose have been established (ICRP 26 and ICRP 60), they depend heavily on the ability to estimate the dose to radiosensitive organs from the CT procedure. However, dete...

متن کامل

The Devil Is in the Details! On Regulating Cannabis Use in Canada Based on Public Health Criteria; Comment on “Legalizing and Regulating Marijuana in Canada: Review of Potential Economic, Social, and Health Impacts”

This commentary to the editorial of Hajizadeh argues that the economic, social and health consequences of legalizing cannabis in Canada will depend in large part on the exact stipulations (mainly from the federal government) and on the implementation, regulation and practice of the legalization act (on provincial and municipal levels). A strict regulatory framework is necessary to minimize the ...

متن کامل

Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter...

متن کامل

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

متن کامل

Comparison of 6 PET scanners, a simulation study [Persian]

Introduction: Due to the large number of PET systems available in the market, it is not very easy to decide about the scanner of choice. Conducting a research in order to compare all different PET scanners is very time consuming and expensive and practically impossible. However, such comparison may be conducted using PET simulators. In this study, the performance of 6 different PET scanne...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007