Some Factors Affecting Alpha Particle Detection In Liquid Scintillation Spectrometry

نویسندگان

  • Laurl Kaihola
  • Timo Oikari
چکیده

Pulse shape analyzers have been introduced in commercial liquid scintillation counters, such as the WaIlac 1220 QuantulusTM and 1219 SM, enabling separation of alpha particle spectra from other types of radiation in a single measurement and making ultra sensitive alpha counting possible. Background count rates as low as one count per day for 214Po in a teflon vial are achievable while still retaining nearly 100% counting efficiency. The number of photons per decay event however, is relatively low in liquid scintillation counting, leading to energy resolution of the order of 10%. Energy resolution has been found to improve with low water to cocktail ratios and opaque vial types. Easy and fast sample preparation together with the ultra low background make liquid scintillation spectrometry a competitive method in environmental counting of alpha particles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation of nanocomposite scintillator of ZnS doped with Ag, Cu and AgCu for alpha particle detection

ZnS nanoparticles (NPs) doped with ‎Ag‎, ‎Cu‎, ‎and AgCu were synthesized using hydrothermal‎ ‎method in water solution‎. ‎The NPS are characterized by X-ray diffraction (XRD)‎, ‎energy-dispersive‎ ‎X-ray spectroscopy scanning (EDX)‎, ‎scanning electron‎ ‎microscopy (SEM) and dynamic light scattering (DLS)‎. ‎The produced NPs have approximately hexagonal structure and a cubic zinc blended struc...

متن کامل

Optimization Method to Determine Gross Alpha-Beta in Water Samples Using Liquid Scintillation Counter

Liquid scintillation counting (LSC) is an adequate nuclear technique to determine radioactivity levels, as verified by this study for the determination of the gross alpha and beta activities of aqueous samples because of its simplicity and low associated cost comparison with other techniques. This paper discusses a new approach to the monitoring of gross alpha and gross beta activities in water...

متن کامل

ON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER

An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...

متن کامل

Measurement of radium micro-precipitates using alpha spectrometry and total alpha counting methods

Background: This study consists of two parts. The first part deals with both qualitative and quantitative analysis of 226Ra using alpha spectrometry measurement method. In the second part, the percentage of radioactive equilibrium between 226 Ra and its daughter products were determined by alpha spectrometry and total alpha measurement system after elapsed time of 15 days from precipitation. Ma...

متن کامل

Determination of uranium isotopes in food and environmental samples by different techniques: a comparison.

The uranium concentration in 59 samples of bottled and tap water, mainly from northern Italy, was measured by different techniques. Results obtained by inductively coupled plasma mass spectrometry (ICP-MS), semiconductor alpha spectrometry and low level liquid scintillation counting with alpha/beta discrimination (LSC) have been compared. High resolution gamma spectrometry and semiconductor alp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008