LC-MS/MS sensitivity enhancement using 2D-SCX/RPLC and its application in the assessment of pharmacokinetics of clonidine in dried blood spots.
نویسندگان
چکیده
BACKGROUND Dried blood spot (DBS) technology offers distinctive preclinical and clinical advantages primarily ascribed to microscale sampling (e.g., 40-80 µl per time point), and the nature of solid-state samples in filter papers. Logistic benefits in sample collection, storage and shipping also result. However, the effective DBS samples available for bioanalysis are finite, that is, in the order of approximately 1 µl equivalent of plasma (3-mm punch) from a DBS of approximately 15-20 µl whole blood samples. This represents 20- to 100-times fewer samples for bioanalysis compared with a typical plasma assay. It is critical to increase LC-MS/MS sensitivity to accommodate DBS bioanalysis. RESULTS We developed a 2D strong cation exchange reversed-phase LC-MS/MS (2D-SCX/RPLC-MS/MS) for online enrichment, separation and detection of basic polar compounds, using clonidine hydrochloride as a model compound. Positively charged clonidine was retained and enriched in the first dimensional SCX column even in large volumes, eluted to a second dimensional RP column with ammonium acetate, de-salted with highly aqueous solvent and separated in an analytical RP column. Injection of 100 µl clonidine extract exhibited essentially the same peak shape as that from 1 µl and the response of clonidine increased quantitatively in the range of 1-100 µl. CONCLUSION The method was successfully employed to analyze clonidine DBS samples from an in-house toxicology study, where clonidine hydrochloride was administered to cynomolgus monkeys to produce hypotensive effects. Of 55 DBS samples collected post-dose, a total of 52 samples were within the curve range of 0.1-50 ng/ml, where valid clonidine PK profiles were obtained. The PK parameters agreed well with the onset of hemodynamic changes measured with implanted miniature telemetry blood pressure transmitters. In comparison, only 21 samples were within the curve range of 2 to 1000 ng/ml from a HILIC-MS/MS method, which limited useful injection volume to 5 µl.
منابع مشابه
Identifying Monoclonal Antibody Mutation Sites Using the Agilent 1290 Infinity II 2D-LC Solution with Q-TOF LC/MS
In recent years, 2D-LC has been highly promising for the detailed characterization and comparability assessment of protein biopharmaceuticals such as monoclonal antibodies. This Application Note describes the use of the Agilent 1290 Infinity II 2D-LC solution in the comparison of an infliximab originator and candidate biosimilar. RPLC×RPLC and SCX×RPLC peptide mapping revealed important differe...
متن کاملDual-purpose sample trap for on-line strong cation-exchange chromatography/reversed-phase liquid chromatography/tandem mass spectrometry for shotgun proteomics. Application to the human Jurkat T-cell proteome.
A dual-purpose sample-trapping column is introduced for the capacity enhancement of proteome analysis in on-line two-dimensional nanoflow liquid chromatography (strong cation-exchange chromatography followed by reversed-phase liquid chromatography) and tandem mass spectrometry. A home-made dual trap is prepared by sequentially packing C18 reversed-phase (RP) particles and SCX resin in a silica ...
متن کاملMethod development for simultaneous determination of 41 pesticides in rice using LC-MS/MS technique and its application for the analysis of 60 rice samples collected from Tehran market
For the first time, a multi-residue methodfor simultaneous determination of 41LC-amenable pesticides in rice, belonging to different chemical classes has been developed in Iran by LC-MS/MS. The pesticides were analyzed simultaneously in a single run using positive electrospray ionization with multiple reaction monitoring (MRM) after extraction with slightly modified QuEChERS method. The calibra...
متن کاملMethod development for simultaneous determination of 41 pesticides in rice using LC-MS/MS technique and its application for the analysis of 60 rice samples collected from Tehran market
For the first time, a multi-residue methodfor simultaneous determination of 41LC-amenable pesticides in rice, belonging to different chemical classes has been developed in Iran by LC-MS/MS. The pesticides were analyzed simultaneously in a single run using positive electrospray ionization with multiple reaction monitoring (MRM) after extraction with slightly modified QuEChERS method. The calibra...
متن کاملMethod validation of clonidine hydrochloride in human plasma by LC-MS technique
A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Bioanalysis
دوره 3 14 شماره
صفحات -
تاریخ انتشار 2011