Carbon nanofiber-filled conductive silicone elastomers as soft, dry bioelectronic interfaces

نویسندگان

  • Geoffrey A Slipher
  • W David Hairston
  • J Cortney Bradford
  • Erich D Bain
  • Randy A Mrozek
چکیده

Soft and pliable conductive polymer composites hold promise for application as bioelectronic interfaces such as for electroencephalography (EEG). In clinical, laboratory, and real-world EEG there is a desire for dry, soft, and comfortable interfaces to the scalp that are capable of relaying the μV-level scalp potentials to signal processing electronics. A key challenge is that most material approaches are sensitive to deformation-induced shifts in electrical impedance associated with decreased signal-to-noise ratio. This is a particular concern in real-world environments where human motion is present. The entire set of brain information outside of tightly controlled laboratory or clinical settings are currently unobtainable due to this challenge. Here we explore the performance of an elastomeric material solution purposefully designed for dry, soft, comfortable scalp contact electrodes for EEG that is specifically targeted to have flat electrical impedance response to deformation to enable utilization in real world environments. A conductive carbon nanofiber filled polydimethylsiloxane (CNF-PDMS) elastomer was evaluated at three fill ratios (3, 4 and 7 volume percent). Electromechanical testing data is presented showing the influence of large compressive deformations on electrical impedance as well as the impact of filler loading on the elastomer stiffness. To evaluate usability for EEG, pre-recorded human EEG signals were replayed through the contact electrodes subjected to quasi-static compressive strains between zero and 35%. These tests show that conductive filler ratios well above the electrical percolation threshold are desirable in order to maximize signal-to-noise ratio and signal correlation with an ideal baseline. Increasing fill ratios yield increasingly flat electrical impedance response to large applied compressive deformations with a trade in increased material stiffness, and with nominal electrical impedance tunable over greater than 4 orders of magnitude. EEG performance was independent of filler loading above 4 vol % CNF (< 103 ohms).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical Resistivity and Contact Resistance of Electrically Conductive Silicones

Cable accessories for mediumand high voltage applications contain field grading and field zoning parts or layers. These parts often consist of electrically conductive silicone elastomers. The electrical conductivity is achieved by using selected and long-term tested carbon blacks. Conductive layers and parts are used to provide safety against exposure, inner shielding and an electrical contact ...

متن کامل

Ultrastretchable Strain Sensors Using Carbon Black-Filled Elastomer Composites and Comparison of Capacitive Versus Resistive Sensors

DOI: 10.1002/admt.201700284 system.[11] Researchers have developed highly stretchable strain sensors made of compliant elastomers and various conductive materials, such as silver nanowire,[12] carbon nanotube (CNT),[13–18] carbon grease,[19] graphene,[20] graphite,[21] laser-carbonized polyimide,[22] conductive acrylic elastomer,[10] liquid metal,[23,24] ionic liquid,[25–27] and conductive fabr...

متن کامل

Soft and Stretchable Sensor Using Biocompatible Electrodes and Liquid for Medical Applications

This article introduces a soft and stretchable sensor composed of silicone rubber integrating a conductive liquid-filled channel with a biocompatible sodium chloride (NaCl) solution and novel stretchable gold sputtered electrodes to facilitate the biocompatibility of the sensor. By stretching the sensor, the cross section of the channel deforms, thus leading to a change in electrical resistance...

متن کامل

Soft and Stretchable Sensor Using Biocompatible Electrodes and Liquid

This article introduces a soft and stretchable sensor composed of silicone rubber integrating a conductive liquidfilled channel with a biocompatible sodium chloride (NaCl) solution and novel stretchable gold sputtered electrodes to facilitate the biocompatibility of the sensor. By stretching the sensor, the cross section of the channel deforms, thus leading to a change in electrical resistance....

متن کامل

Semi Cylindrical Fluid Filled Hyperelastic Finger Model for Soft Contact

In this paper a semi cylindrical fluid filled hyperelastic finger model for soft contact has been developed from the basic principles of mechanics. The deformation parameters namely contact width and radial deflection were calculated for different applied forces. To validate this analytical model, compression tests were conducted on silicone rubber finger specimens . Contact width and radial de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2018