Correct measurement of height is important when assessing lung function values.

نویسندگان

  • Sidsel Bendixen Holm Renstrøm
  • Christian Skjoldvang Andersen
  • Camilla Helene Borup Pedersen
  • Flemming F Madsen
چکیده

INTRODUCTION Measurement of stature is a prerequisite for determination of the normal lung function since reference equations are based on stature (standing height). We investigated the optimal method for measuring stature and for testing the current practice. MATERIAL AND METHODS We measured the stature of 87 subjects using a digital-counter stadiometer and a wall-mounted bench rule. Stature was also estimated based on finger-reach measurement, and self-reported stature was recorded. Results were compared using Altman-Bland plots. An email survey asking about written instruction on the practice for measuring stature was performed. RESULTS The Harpenden stadiometer delivered results reproducible within ± 0.29 cm and the bench rule compared with the Harpenden stadiometer yielded results within ± 0.59 cm. The Harpenden stadiometer was the faster of the two methods. With two exceptions, Danish lung function laboratories did not use a written instruction on measurement of stature in our sample. CONCLUSION It is necessary to focus on correct measurement of stature. Measurement of stature can be performed accurately with stadiometers with either digital or analogue counters. The digital stadiometer was the faster of the two. FUNDING Not relevant. TRIAL REGISTRATION Not relevant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reference equations for spirometric indices from a sample of the general adult population in Nigeria

BACKGROUND The increasing importance of pulmonary function testing in diagnosing and managing lung diseases and assessing improvement has necessitated the need for locally derived reference equations from a sample of the general Nigerian population. METHODS It was a cross sectional study in which we used linear regression models to obtain equations for reference values and lower limits of nor...

متن کامل

MOCA ARM: Analog Reliability Measurement based on Monte Carlo Analysis

Due to the expected increase of defects in circuits based on deep submicron technologies, reliability has become an important design criterion. Although different approaches have been developed to estimate reliability in digital circuits and some measuring concepts have been separately presented to reveal the quality of analog circuit reliability in the literature, there is a gap to estimate re...

متن کامل

Lung function parameters of healthy Sri Lankan Tamil young adults.

OBJECTIVES To establish reference norms of lung function parameters for healthy Sri Lankan Tamil young adults. DESIGN AND SETTING Cross sectional study of Tamil students at the Faculty of Medicine, Jaffna. MEASUREMENTS Healthy non smoking students of Sri Lankan Tamil ethnic group were enrolled. Age, height, weight, BMI and spirometric measurements (Micro Quark) were recorded in 267 particip...

متن کامل

The Correlation of Brody High Resolution Computed Tomography Scoring System with Clinical Status and Pulmonary Function Test in Patients with Cystic Fibrosis

Background: To reduce the mortality and morbidity rates of cystic fibrosis (CF) patients, and to have an effective clinical management, it is important to monitor the progression of the disease. The aim of this study was to evaluate the progression of lung disease in CF patients by means of assessing the correlation of the CT scoring system with clinical status and pulmonary function test at th...

متن کامل

Prediction formulae for lung function parameters in females of south eastern Nigeria.

This study was carried out to obtain normal lung function values for women in south eastern Nigeria with a view to establishing prediction equations for forced vital capacity (FVC), forced expiratory volume at the first second (FEV(1)) and peak expiratory flow rate (PEFR). Lung function values were measured in 600 apparently healthy Nigerian women aged between 18 and 57 years. FVC and FEV1 were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Danish medical journal

دوره 59 2  شماره 

صفحات  -

تاریخ انتشار 2012