Steel Grounding Design Guide and Application Notes

نویسندگان

  • P. K. Sen
  • Keith Malmedal
  • John P. Nelson
چکیده

Based on the National Bureau of Standards [presently called The National Institute of Standards and Technology or “NIST”] statistical data on corrosion of steel, an equation is introduced to estimate the corrosion rate of underground steel. The variables include the major soil characteristics (parameters), namely: resistivity, pH value, moisture content and aeration. This formula, together with the IEEE Standard No. 80-2000 , is used in the design of steel grounding. Also discussed, in detail, the design procedures for cathodic protection scheme to minimize corrosion of steel grounding. Numerical examples are included in the paper to enhance the understanding of steel grounding design for high voltage AC substations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modern Computational Methods for the Design and Analysis of Power System Grounding

This paper examines a few methods used in grounding analysis and illustrates the advantages, limitations, and the applicability of these methods. Computation results using these methods are presented and compared. The various cases modeled in this paper include grounding networks of different sizes, grounding networks with buried metallic structures such as steel pipes, and high frequency cases...

متن کامل

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV software. The related transient modeling of the grounding systems is based on a transmission line (TL) model with considering the soil ionization....

متن کامل

ECM - 0707 IPQ.indd

ite power and grounding audits/evaluations of commercial and industrial locations routinely identify electrical power system grounding and bonding problems. According to S. Frank Waterer, an electrical engineering IEEE Fellow at Schneider Electric with more than 30 years of experience, approximately 70% of all anomalies, dysfunctions, or problems associated with power distribution systems are d...

متن کامل

Application of guide blades for improving performance of savonius wind turbine

Application of guide blades is an appropriate method for improving aerodynamic performance of savonius wind turbine. Guide blades gather the wind energy around the turbine and guide them into the concave side of savonius rotor. In this paper, numerical investigation is conducted for evaluating effect of the guide blades on the performance of savonius turbine. Aerodynamic performance of the turb...

متن کامل

Analysis of a Large Grounding System and Subsequent Field Test Validation Using the Fall of Potential Method

This paper examines various aspects of the design process and subsequent field test measurements of a large and complex substation grounding system. The study and measurements show that soil layering and lead interference can have a significant impact on the appropriate test location that yields the exact substation ground impedance. Applying a specific percentage rule such as the 61.8% rule fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003