A retrospective study of canine D-dimer concentrations measured using an immunometric "Point-of-Care" test.
نویسندگان
چکیده
OBJECTIVES To measure the D-dimer concentrations in both healthy dogs and dogs with and without evidence of thromboembolic disease/disseminated intravascular coagulation using a "Point-of-Care" test. METHODS Sixty-seven clinical cases and 26 healthy dogs were included in this retrospective study. D-dimer was measured using the NycoCard D-dimer test. Clinical conditions were categorised based on clinical findings, laboratory results, imaging, cytology, histopathology, necropsy or a combination of these tests. RESULTS There were no dogs for which the NycoCard D-dimer test did not produce a result. The D-dimer range in clinically healthy dogs was 0.1 to 0.5 mg/l (median 0.2 mg/l). In eight of nine cases with thromboembolic disease/disseminated intravascular coagulation and 43 of 58 of the cases without thromboembolic disease/disseminated intravascular coagulation , the D-dimer concentrations were greater than those of healthy dogs. CLINICAL SIGNIFICANCE The NycoCard D-dimer test card required no specialised equipment and could therefore facilitate rapid screening for thromboembolic disease/disseminated intravascular coagulation in first opinion practice. Elevations in D-dimer concentration can be found in a number of clinical conditions apart from thromboembolic disease/disseminated intravascular coagulation and should not therefore be used as the sole basis of diagnosis. D-dimer may be considered a good screening test for thromboembolic disease/disseminated intravascular coagulation as only one case with histopathological evidence of thromboembolic disease/disseminated intravascular coagulation had a D-dimer concentration in the range seen in healthy dogs.
منابع مشابه
Evaluation of Correlation between D-dimer Levels with Disease Severity in Patients with Covid-19 Referred to Hamedan Besat Hospital in 2021-2022
Introduction: The Covid-19 virus affects the hemostasis system in infected people by causing thrombosis and it increases the level of D_dimer. This study was designed and conducted for the evaluation of correlation between D-dimer levels with disease severity in patients with Covid-19 referred to Hamedan Besat hospital. Methods and Materials: 366 patients with Covid-19 referred to Besat Hospit...
متن کاملThe value of D-Dimer as a biomarker in assessing disease severity and mortality in patients with Covid-19, a review study
The Covid-19 pandemic created by the 2019 Coronavirus-nCov has become one of the biggest health problems of the current century. Because this disease is new in human society and has no previous history, so our information about it is incomplete, and researchers are trying to study with extensive clinical studies and changes in the human body caused by the function of this virus. It is clear tha...
متن کاملPlasma Fibrinogen and D-dimer in Children With Sepsis: A Single-center Experience
Background & Objectives: In sepsis, enhanced fibrin formation, impaired fibrin degradation, and intravascular fibrin deposition lead to a prothrombotic state. The current study aimed at measuring various coagulation parameters to predict an early marker for disseminated intravascular coagulation (DIC). Methods: The current prospective s...
متن کاملResearch Paper: The Prevalence of Ectopically Maxillary Canine and Related Factors in an Iranian Population: A Retrospective Study
Abstract Introduction: Maxillary canines commonly have an ectopic eruption. This study aimed to assess the factors related to the ectopic maxillary permanent canines. Materials and Methods:This was a descriptive cross-sectional study of 1357 panoramic radiographs from patients 8 to 13 years old. The radiography was excluded if the patient had any developmental disease or if the panoramic im...
متن کاملA unitized enzyme-labeled immunometric digoxin assay suitable for rapid testing.
An enzyme-labeled immunometric assay has been developed for measuring digoxin concentrations in serum or plasma. Unitized, compartmentalized reagents are used with an automated sample-processing instrument. The enzyme activity of the processed sample, which is directly proportional to the digoxin concentration, is measured by using a reagent strip and the Ames Seralyzer reflectance photometer. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of small animal practice
دوره 49 7 شماره
صفحات -
تاریخ انتشار 2008