Study of ExacTrac X‐ray 6D IGRT setup uncertainty for marker‐based prostate IMRT treatment

نویسندگان

  • Chengyu Shi
  • Adam Tazi
  • Deborah Xiangdong Fang
  • Christopher Iannuzzi
چکیده

Novalis Tx ExacTrac X-ray system has the 6D adjustment ability for patient setup. Limited studies exist about the setup uncertainty with ExacTrac X-ray system for IMRT prostate treatment with fiducial markers implanted. The purpose of this study is to investigate the marker-based prostate IMRT treatment setup uncertainty using ExacTrac 6D IGRT ability for patient setup. Forty-three patients with prostate cancers and markers implanted have been treated on the Novalis Tx machine. The ExacTrac X-ray system has been used for the patient pretreatment setup and intratreatment verification. In total, the shifts data for 1261 fractions and 3504 correction times (the numbers of X-ray images were taken from tube 1 and tube 2) have been analyzed. The setup uncertainty has been separated into uncertainties in 6D. Marker matching uncertainty was also analyzed. Correction frequency probability density function was plotted, and the radiation dose for imaging was calculated. The minimum, average, and maximum translation shifts were: -5.12 ± 3.89 mm, 0.20 ± 2.21 mm, and 6.07 ± 4.44 mm, respectively, in the lateral direction; -6.80 ± 3.21 mm, -1.09 ± 2.21 mm, and 3.12 ± 2.62 mm, respectively, in the longitudinal direction; and -7.33 ± 3.46 mm, -0.93 ± 2.70 mm, and 5.93 ± 4.85mm, respectively, in the vertical direction. The minimum, average, and maximum rotation shifts were: -1.23° ± 1.95°, 0.25° ± 1.30°, and 2.38° ± 2.91°, respectively, along lateral direction; -0.67° ± 0.91°, 0.10° ± 0.61°, and 1.51° ± 2.04°, respectively, along longitudinal direction; and -0.75° ± 1.01°, 0.02° ± 0.50°, and 0.82° ± 1.13°, respectively, along vertical direction. On average, each patient had three correction times during one fraction treatment. The radiation dose is about 3 mSv per fraction. With the ExacTrac 6D X-ray system, the prostate IMRT treatment with marker implanted can achieve less than 2 mm setup uncertainty in translations, and less than 0.25° in rotations as overall interfraction mean error. The imaging dose is less than kV (CBCT) for setup verification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Reproducibility of Patient Setup for Head and Neck Cancers Treated with Image-Guided and Intensity-Modulated Radiation Therapies Using Thermoplastic Immobilization Device

The reproducibility of patient setup is an important issue for head and neck cancers treated with intensity-modulated radiation therapy (IMRT). In this study, an image-guided radiation therapy (IGRT) system has been used to minimize the uncertainty of patient setup while standard thermoplastic masks were used to provide adequate immobilization for the head and neck. However, they do not provide...

متن کامل

Quantitative evaluation of patient setup uncertainty of stereotactic radiotherapy with the frameless 6D ExacTrac system using statistical modeling

The purpose of this study is to evaluate patient setup accuracy and quantify indi-vidual and cumulative positioning uncertainties associated with different hardware and software components of the stereotactic radiotherapy (SRS/SRT) with the frameless 6D ExacTrac system. A statistical model is used to evaluate positioning uncertainties of the different components of SRS/SRT treatment with the Br...

متن کامل

[Comparison of setup accuracy between ExacTrac X-ray 6 dimensions and cone-beam computed tomography for intracranial and pelvic image-guided radiotherapy].

The aim of this study was to compare the setup difference measured with ExacTrac X-ray 6D (ETX6D) and cone-beam computed tomography (CBCT) for non-invasive fractionated radiotherapy. Setup data were collected on a Novalis Tx treatment unit for both a head phantom and patients with intracranial tumors and a pelvic phantom and patients with prostate cancer. Initially, setup was done for a phantom...

متن کامل

Superiority of a soft tissue‐based setup using cone‐beam computed tomography over a bony structure‐based setup in intensity‐modulated radiotherapy for prostate cancer *

The purpose of this study was to test the superiority of a soft tissue-based setup using cone-beam computed tomography (CBCT) to a bony structure-based setup using the ExacTrac system in intensity-modulated radiotherapy (IMRT) for prostate cancer. We studied 20 patients with localized prostate cancer who received IMRT between November 2010 and February 2012. After the initial setup, the pelvic ...

متن کامل

Evaluations of the setup discrepancy between BrainLAB 6D ExacTrac and cone-beam computed tomography used with the imaging guidance system Novalis-Tx for intracranial stereotactic radiosurgery

The objective of this study was to evaluate the setup discrepancy between BrainLAB 6 degree-of-freedom (6D) ExacTrac and cone-beam computed tomography (CBCT) used with the imaging guidance system Novalis Tx for intracranial stereotactic radiosurgery. We included 107 consecutive patients for whom white stereotactic head frame masks (R408; Clarity Medical Products, Newark, OH) were used to fix th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2012