A Q-band pulse EPR/ENDOR spectrometer and the implementation of advanced one- and two-dimensional pulse EPR methodology.

نویسندگان

  • I Gromov
  • J Shane
  • J Forrer
  • R Rakhmatoullin
  • Y Rozentzwaig
  • A Schweiger
چکیده

A versatile high-power pulse Q-band EPR spectrometer operating at 34.5--35.5 GHz and in a temperature range of 4--300 K is described. The spectrometer allows one to perform one- and two-dimensional multifrequency pulse EPR and pulse ENDOR experiments, as well as continuous wave experiments. It is equipped with two microwave sources and four microwave channels to generate pulse sequences with different amplitudes, phases, and carrier frequencies. A microwave pulse power of up to 100 W is available. Two channels form radiofrequency pulses with adjustable phases for ENDOR experiments. The spectrometer performance is demonstrated by single crystal pulse ENDOR experiments on a copper complex. A HYSCORE experiment demonstrates that the advantages of high-field EPR and correlation spectroscopy can be combined and exploited at Q-band. Furthermore, we illustrate how this combination can be used in cases where the HYSCORE experiment is no longer effective at 35 GHz because of the shallow modulation depth. Even in cases where the echo modulation is virtually absent in the HYSCORE experiment at Q-band, matched microwave pulses allow one to get HYSCORE spectra with a signal-to-noise ratio as good as at X-band. Finally, it is shown that the high microwave power, the short pulses, and the broad resonator bandwidth make the spectrometer well suited to Fourier transform EPR experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

55Mn-ENDOR of the S2-state multiline signal of Photosystem II from Thermosynechococcus elongatus.

Pulse EPR and 55Mn-ENDOR (electron nuclear double resonance) experiments at 34 GHz (Q-band) were performed on the S2 state of the OEC (oxygen-evolving complex) in PSII (Photosystem II) from Thermosynechococcus elongatus. The ENDOR spectra are discussed with respect to earlier data obtained from X- (9 GHz) and Q-band experiments on PSII preparations from spinach with and without the addition of ...

متن کامل

A W-band pulsed ENDOR spectrometer: setup and application to transition metal centers.

The design and performance of a 95 GHz pulsed W-band EPR/ENDOR spectrometer is described with emphasis on the ENDOR part. Its unique feature is the easy and fast sample exchange at 4.2 K for frozen solution and single crystal samples. In addition, the microwave bridge power output is relatively high (maximum 267 mW), which allows the application of short microwave pulses. This increases the sen...

متن کامل

X-Band EPR Spectrometer with Customizable Arbitrary Waveform Generator based on a 1 GHz DAC Board

We present an EPR spectrometer featuring an arbitrary waveform generator (AWG) operating at 8–10 GHz (X-band) that is based on a 1 GHz digital-to-analog converter (DAC) boardwith a 42 dB (i.e. 14-bit) dynamic range. This AWG-capable spectrometer was developedto widen the scope of pulsed electron paramagnetic resonance (EPR) and enable new experiments. It generates shaped X-band pulses with prec...

متن کامل

Photochemical processes in photosynthesis studied by advanced electron paramagnetic resonance techniques *

Various continuous-wave and pulse electron paramagnetic resonance (EPR) and electron nuclear double resonance (ENDOR) experiments performed on the radical species occurring in photosynthetic reaction centers of plants and bacteria during light-induced charge separation are reviewed here. Emphasis is placed on time-resolved experiments performed on short-lived intermediate states such as radical...

متن کامل

Pulsed 180-GHz EPR/ENDOR/PELDOR spectroscopy.

Within this review, we describe a home-built pulsed electron paramagnetic resonance (EPR) spectrometer operating at 180 GHz as well as the incorporation of two double resonance techniques, electron nuclear double resonance (ENDOR) and pulsed electron double resonance (PELDOR), along with first applications. Hahn-echo decays on a TEMPO/polystyrene sample are presented, demonstrating that the obs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 149 2  شماره 

صفحات  -

تاریخ انتشار 2001