Entropy and bispectral index for assessment of sedation, analgesia and the effects of unpleasant stimuli in critically ill patients: an observational study

نویسندگان

  • Matthias Haenggi
  • Heidi Ypparila-Wolters
  • Christine Bieri
  • Carola Steiner
  • Jukka Takala
  • Ilkka Korhonen
  • Stephan M Jakob
چکیده

INTRODUCTION Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning. METHODS Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention. RESULTS The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation. CONCLUSIONS Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inadequate Sedation During Therapeutic Paralysis: Use of Bispectral Index in Critically Ill Patients

BACKGROUND Patients receiving therapeutic paralysis may experience inadequate sedation due to intrinsic limitations of behavioral sedation assessment. Bispectral index (BIS™) provides an objective measure of sedation; however, the role of BIS™ is not well defined in intensive care unit (ICU) patients on neuromuscular blocking agents (NMBA). OBJECTIVE The aim of this study was to delineate the...

متن کامل

Frontal EEG for intensive care unit sedation: treating numbers or patients?

In this issue of Critical Care, Dr Haenggi and co-workers present a study evaluating bispectral index (BIS), state entropy (SE) and response entropy in 44 patients sedated in the intensive care unit (ICU). As in recent studies attempting to correlate frontal electroencephalogram (EEG) measurements with clinical evaluations of sedative efficacy, there is considerable overlap in numerical EEG val...

متن کامل

تاثیر سن بالا بر روی شاخص دو طیفی (Bispectral Index) قبل و بعد از تزریق آرام‌بخش: یک مطالعه آینده‌نگر

Background: The Bispectral Index (BIS) is an EEG-derived value that measures the sedative and hypnotic component of the anesthetic state. The effects of age on the bispectral index have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and bispectral index in awake and in patients with sedation induced by midazolam.Methods...

متن کامل

Validation of the bispectral index monitor during conscious and deep sedation in children.

UNLABELLED In this study, we tested the validity of the bispectral index (BIS) monitor during conscious and deep sedation of children by comparing it with the University of Michigan Sedation Scale (UMSS), a validated observational pediatric sedation scale. Eighty-six children <12 yr of age were enrolled in this observational study. The subjects underwent conscious or deep sedation administered ...

متن کامل

The use of bispectral index monitors in paediatric intensive care

The bispectral index (BIS) is a processed neurophysiological electroencephalographic parameter that may be used to evaluate the depth of sedation in critically ill children. Triltsch and colleagues attempted to correlate BIS scores with a commonly used clinical sedation scoring system. They were able to demonstrate good correlation during deep sedation and in cases where the electrical impedanc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2008