Design of a Graphical User Interface to Control Voltage and Reactive Power by Using Nine-area Diagram
نویسندگان
چکیده
For a primary substation (P/S), there are many typical methods to control voltage and reactive power such as adjusting the generator mode, switching shunt capacitor (SC), adjusting on-load tap changer (OLTC), and switching shunt reactor (SR). In this study, a graphical user interface (GUI) is designed combining with nine-area diagram to observe the relationship between voltage and reactive power in a P/S. This GUI not only predicts the effect to dispatchers in short time but also analyzes the sensitivity parameters. Field measurement data were analyzed. Simulation results confirmed the feasibility of compensating the reactive power and adjusting voltage simultaneously. Keyword: Substations, Voltage, Reactive Power, Nine-area Diagram, Sensitivity.
منابع مشابه
Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate
The doubly fed induction generator (DFIG) is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE) event is among the most frequent failures in electric generators. However, LOE detection stud...
متن کاملUser Interface Design in Mobile Educational Applications
Introduction: User interfaces are a crucial factor in ensuring the success of mobile applications. Mobile Educational Applications not only provide flexibility in learning, but also allow learners to learn at any time and any place. The purpose of this article is to investigate the effective factors affecting the design of the user interface in mobile educational applications. Methods: Quantita...
متن کاملReactive Power Sharing and Harmonic Voltage Modification in Single Phase Island Micro-Grid with Drop Control
Abstract: When several parallel inverters are in islands operating mode, the droop control scheme is usually used to control the inverters. The droop control method enables the inverters of a Micro-Grid to control the voltage and frequency of the network in a decentralized regulation behavior. The drop control method also enables the inverters to share the required active and reactive powers of...
متن کاملA Local Power Control Scheme for Electronically Interfaced Distributed Generators in Islanded Microgrids
The conventional real power-frequency and reactive power-voltage droop characteristics are commonly employed to share the electric power among parallel distributed generation (DG) units. Despite some advantages such as easy implementation and no need for communication infrastructure, inaccurate reactive power sharing is one of the main disadvantages of conventional droop control. This paper pre...
متن کاملA Fast Voltage Collapse Detection and Prevention Based on Wide Area Monitoring and Control
Voltage stability is one of the most important factors in maintaining reliable operation of power systems. When a disturbance occurs in the power system, it usually causes instabilities and sometimes leads to voltage collapse (VC). To avoid such problems, a novel approach called Vector Analysis (VA) is proposed that exploits a new instability detection index to provide wide area voltage stabili...
متن کامل