Characterization of acute and chronic myocardial infarcts by multidetector computed tomography: comparison with contrast-enhanced magnetic resonance.

نویسندگان

  • Bernhard L Gerber
  • Bénédicte Belge
  • Gabin J Legros
  • Pascal Lim
  • Alain Poncelet
  • Agnès Pasquet
  • Giovanna Gisellu
  • Emmanuel Coche
  • Jean-Louis J Vanoverschelde
چکیده

BACKGROUND We evaluated whether contrast-enhanced multidetector computed tomography (CE-MDCT) might characterize myocardial infarct (MI) with patterns similar to those obtained by contrast-enhanced magnetic resonance (CE-MR) and studied the underlying mechanisms. METHODS AND RESULTS In vivo infarct characterization by CE-MDCT was shown to be feasible between 4 and 20 minutes after contrast injection in 7 pigs with MI. Subsequently, in 16 patients with acute MI and 21 patients with chronic MI, contrast patterns by CE-MDCT were related to CE-MR. Eighteen patients had hypoenhanced regions on early CE-MDCT images at the time of coronary imaging, and 34 patients had hyperenhanced regions on images acquired 10 minutes later. On a segmental basis, there was moderately good concordance of early hypoenhanced regions (92%, kappa=0.54, P<0.001) and late hyperenhanced regions (82%, kappa=0.61, P<0.001) between CE-MDCT and CE-MR. Absolute sizes of early hypoenhanced (6+/-16 versus 7+/-16 g, P=0.25) and late hyperenhanced (36+/-34 versus 31+/-40 g, P=0.14) regions were similar on CE-MDCT and CE-MR and were highly correlated (r=0.93, P<0.001 and r=0.89, P<0.001 respectively). In 8 retrogradely perfused infarcted rabbit hearts, contrast kinetics of iomeprol were similar to gadodiamide, ie, slow wash in (8.7+/-6.7 versus 1.2+/-0.3 minutes, P<0.001) in infarct core and slow washout (20+/-12 versus 2.5+/-0.5 minutes, P<0.001) in both infarct core and rim compared with the remote region. CONCLUSIONS Because iodated contrast agents have similar kinetics in infarcted and noninfarcted myocardium as gadolinium DPTA, CE-MDCT can characterize acute and chronic MI with contrast patterns similar to CE-MR. CE-MDCT may thus provide important information on infarct size and viability at the time of noninvasive coronary imaging.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contrast-enhanced multidetector computed tomography viability imaging after myocardial infarction: characterization of myocyte death, microvascular obstruction, and chronic scar.

BACKGROUND The ability to distinguish dysfunctional but viable myocardium from nonviable tissue has important prognostic implications after myocardial infarction. The purpose of this study was to validate the accuracy of contrast-enhanced multidetector computed tomography (MDCT) for quantifying myocardial necrosis, microvascular obstruction, and chronic scar after occlusion/reperfusion myocardi...

متن کامل

Determination of the myocardial area at risk after reperfused acute myocardial infarction with different imaging techniques: cardiac magnetic resonance imaging, multidetector computed tomography and histopathological validation

Purpose The principal objective of this study was to compare the AAR defined with two different T2 weighted cardiac magnetic resonance (T2W CMR) imaging sequences (TIRM T2w blood suppressed TSE and ACUTE TSESSFP), the contrast-enhanced (ce-) CMR endocardial surface length (ESL) after 90-minutes of reperfusion and the arterial enhanced multi-detector computed tomography (MDCT) performed during o...

متن کامل

Regional heterogeneity of human myocardial infarcts demonstrated by contrast-enhanced MRI. Potential mechanisms.

BACKGROUND Myocardial reperfusion is pivotal to the prognosis of patients with acute myocardial infarction. In these patients, coronary flow is generally assessed by angiography and tissue perfusion by tracer scintigraphy. This study was designed to examine whether magnetic resonance imaging (MRI) provides information on myocardial perfusion and damage beyond that supplied by angiography and th...

متن کامل

Characterization of peri-infarct zone heterogeneity by contrast-enhanced multidetector computed tomography: a comparison with magnetic resonance imaging.

OBJECTIVES This study examined whether multidetector computed tomography (MDCT) improves the ability to define peri-infarct zone (PIZ) heterogeneity relative to magnetic resonance imaging (MRI). BACKGROUND The PIZ as characterized by delayed contrast-enhancement (DE)-MRI identifies patients susceptible to ventricular arrhythmias and predicts outcome after myocardial infarction (MI). METHODS...

متن کامل

Non-invasive diagnosis of focal liver lesions: an individualized approach

Modern cross-sectional imaging with multidetector computed tomography (MDCT) or magnetic resonance imaging (MRI) often reveals small focal liver lesions, which puts pressure on the reporting radiologist to characterize these tiny lesions. On the other hand, in patients with underlying diffuse liver disease, such as cirrhosis or severe steatosis, the detection of focal liver lesions can be quite...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 113 6  شماره 

صفحات  -

تاریخ انتشار 2006