Perfusion index assessment during transition period of newborns: an observational study

نویسندگان

  • Sezin Unal
  • Ebru Ergenekon
  • Selma Aktas
  • Serdar Beken
  • Nilgun Altuntas
  • Ebru Kazanci
  • Ferit Kulali
  • Ibrahim M. Hirfanoglu
  • Esra Onal
  • Canan Turkyilmaz
  • Esin Koc
  • Yildiz Atalay
چکیده

BACKGROUND Perfusion index (PI) is becoming a part of clinical practice in neonatology to monitor peripheral perfusion noninvasively. Hemodynamic and respiratory changes occur in newborns during the transition period after birth in which peripheral perfusion may be affected. Tachypnea is a frequent symptom during this period. While some tachypneic newborns get well in less than 6 h and diagnosed as "delayed transition", others get admitted to intensive care unit which transient tachypnea of newborn (TTN) being the most common diagnosis among them. We aimed to compare PI of neonates with TTN and delayed transition with controls, and assess its value on discrimination of delayed transition and TTN. METHODS Neonates with gestational age between 37 and 40 weeks who were born with elective caesarian section were included. Eligible neonates were monitored with Masimo Set Radical7 pulse-oximeter (Masimo Corp., Irvine, CA, USA). Postductal PI, oxygen saturation and heart rate were manually recorded every 10 s for 3 min for two defined time periods as 10th minute and 1st hour. Axillary temperature were also recorded. Newborn infants were grouped as control, delayed transition, and TTN. RESULTS Forty-nine tachypneic (TTN; 21, delayed transition; 28) and 30 healthy neonates completed the study. PI values were similar between three groups at both periods. There were no correlation between PI and respiratory rate, heart rate, and temperature. CONCLUSION PI assessment in maternity unit does not discriminate TTN from delayed transitional period in newborns which may indicate that peripheral perfusion is not severely affected in either condition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perfusion index in healthy newborns during critical congenital heart disease screening at 24 hours: retrospective observational study from the USA

OBJECTIVE To describe the distribution of perfusion index (PI) in asymptomatic newborns at 24 hours of life when screening for critical congenital heart disease (CCHD) using an automated data selection method. DESIGN This is a retrospective observational study. SETTING Newborn nursery in a California public hospital with ~3500 deliveries annually. METHODS We developed an automated program...

متن کامل

Perfusion index variations in clinically and hemodynamically stable preterm newborns in the first week of life

BACKGROUND The perfusion index, derived from the pulse oximeter signal, seems to be an accurate predictor for high illness severity in newborns. The aim of this study was to determine the perfusion index values of clinically and hemodynamically stable preterm newborns in the first week of life. METHODS Perfusion index recordings were performed on the first, third and seventh day of life on 30...

متن کامل

Hydrodynamics and water quality assessment of a coastal lagoon using environmental fluid dynamics code explorer modeling system

Ciénaga de Mallorquín is a coastal lagoon designated as a RAMSAR site due to its ecological regional and international importance. In this work, the environmental fluid dynamics code explorer modeling system was implemented to determine the spatio-temporal distribution of temperature, dissolved oxygen, chemical oxygen demand and nutrient levels, and assess the trophic status of Ciénaga de Mallo...

متن کامل

First day of life reference values for pleth variability index in spontaneously breathing term newborns.

BACKGROUND The perfusion index (PI), derived from the pulse oximetry signal, has been shown to be an accurate predictor for identifying high illness severity in neonates. The plethysmographic variability index (PVI) is a measure of the dynamic change in PI occurring during a complete respiratory cycle. OBJECTIVES The aim of this study was to establish the reference range of PVI in spontaneous...

متن کامل

Assessment of Body Composition Using Bioelectrical Impedance Analysis in Preterm Neonates Receiving Intensive Care.

AIM Evaluation of bioelectrical impedance values and body composition during early infancy in groups of preterm newborns and full-term newborns. MATERIAL AND METHODS A total of 38 newborns was enrolled in the study: 26 very low birth weight preterm newborns with the mean birth weight of 1236 g (SD: 161) as the study group and 12 term newborns with birth weight of 2500-4000 g as the control gr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016