Bare-metal stents across the Vater's ampulla is a safe method for patients with lower bile duct obstruction
نویسندگان
چکیده
This study explored the effect of the implant position of stents across the Vater's ampulla on treatment outcomes in patients with lower bile duct obstruction.In the retrospective study, 41 patients with malignant obstruction of the lower bile duct and obstructive jaundice received percutaneous transhepatic biliary placement of bare-metal stents. Basic demographic data on patients, such as sex, age, and primary diseases, and follow-up data, including postoperative complications and jaundice-free survival, were recorded. The follow-up data on patients with an involved ampulla, patients with an uninvolved ampulla, patients with a stent across the ampulla, and patients with a stent at a site other than the ampulla were compared. Furthermore, prognostic factors for jaundice- free survival were investigated using Cox proportional hazards regression analysis.Among the 41 patients, 38 patients experienced subsiding of jaundice, whereas 3 cases had unsuccessful stent patency. Whether or not the ampulla was involved did not influence the incidence rates of postoperative complications and the jaundice-free survival time. Notably, when stents were placed across the ampulla, the jaundice-free survival time was significantly longer than when stents were placed at sites other than across the ampulla (P < .05). Furthermore, placement of the stent across the ampulla or at other sites was an independent prognostic factor (hazard ratio = 0.154, 95% confidence interval 0.042-0.560, P = .005) for jaundice-free survival of patients.The current study revealed that the implant position of a stent across the ampulla resulted in maintenance of stent patency and prolongation of the jaundice-free survival time.
منابع مشابه
Endoscopic bilateral stenting of malignant hilar bile duct obstruction using novel partially covered self-expandable metal stents.
Endoscopic bilateral stenting using conventional metal stents is considered to be technically difficult in patients with malignant hilar bile duct obstruction because the second stent is not easily inserted through the cell of the first stent wall in the bile duct [1]. A variety of new self-expandable metal stents (SEMS) specially designed for stent-in-stent procedures to facilitate bilateral s...
متن کاملEndoscopic ultrasound-guided hepaticogastrostomy using two metal stents locked together.
Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is a recently developed technique for biliary decompression in patients with biliary obstruction, which offers an alternative when endoscopic biliary drainage (EBD) or percutaneous transhepatic biliary drainage (PTBD) fail, or when the papilla is inaccessible [1]. However, EUS-HGS has several disadvantages, including early stent occlusi...
متن کاملManagement of common bile duct stricture caused by chronic pancreatitis with metal mesh self expandable stents.
Twenty patients with chronic pancreatitis and signs of biliary obstruction were treated by endoscopic placement of self expandable metal mesh stents, and followed up prospectively. Eleven had been treated previously with plastic endoprostheses. All had persistent cholestasis, seven patients had jaundice, and three overt cholangitis. Endoscopic stent placement was successful in all cases. No ear...
متن کاملPercutaneous Biliary Stent Placement in Palliation of Malignant Bile Duct Obstruction
BACKGROUND To summarize the experiences with the technique of percutaneous biliary stent placement for treatment of malignant biliary obstruction in patients with different types of biliary obstruction. METHODS Percutaneous biliary stent placement was performed in 126 patients with malignant biliary obstruction. The etiology included 56 cases of cholangiocarcinoma, 28 cases of pancreatic canc...
متن کاملNeedle knife sphincterotomy for an impacted ampullary stone with difficult selective biliary cannulation.
Endoscopic treatment is highly effective for extracting common bile duct (CBD) stones and is the most common therapeutic method for CBD stones. For patients with CBD stones, the treatment goal is to completely clear the biliary duct. In general, the successful extraction rate using a basket and/or balloon catheter is as high as 90%. However, stones that are resistant to conventional endoscopic ...
متن کامل