On-line collection/concentration and detection of sulfur dioxide in air by flow-injection spectrophotometry coupled with a chromatomembrane cell.

نویسندگان

  • Piyanete Sritharathikhun
  • Mitsuko Oshima
  • Yanlin Wei
  • Jürgen Simon
  • Shoji Motomizu
چکیده

A simple and rapid procedure for SO2 determination in air was developed by using a flow injection analysis (FIA) system coupled with a 3-hole chromatomembrane cell (CMC). The CMC was applied for the on-line collection/concentration of SO2 from air into a solution of 2 g l(-1) triethanolamine (TEA) solution as an absorbing solution: SO2 was converted to SO3(2-) in the alkaline absorbing solution. The solution containing absorbed SO2 was introduced into the carrier stream of the FIA system. The amount of SO3(2-) in the absorbing solution was measured by spectrophotometry with a mixed reagent of pararosaniline and formaldehyde, and was converted to the concentration of SO2 in the air sample. A calibration graph prepared by using standard sodium sulfite aqueous solutions was adopted for the determination of SO3(2-) in the absorbing solution. The SO2 concentration in indoor air examined was found to be 22.7 +/- 0.2 ppbv using 20 ml of air sample with the air flow rate of 5 ml min(-1), where the relative standard deviation was 1.7%. The detection limit for aqueous solutions and air samples were 6.9 x 10(-8) M and 0.48 ppbv, respectively. The measuring time for one sample was about 10 min when a 20 ml air sample was used. The interferences from common anionic species, formaldehyde and acetaldehyde, were also examined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تأثیر کاربرد سورفکتانتها به‌همراه آب‌آهک و بیکربنات‌سدیم در حذف دی اکسیدگوگرد در اسکرابر بستردار

Background and aims: The emission of sulfur dioxide in air has hazardous effects on human health and environment. In this research the use of surfactants with sodium bicarbonate and limestone for the removal of sulfur dioxide was studied. Methods: A packed scrubber was used and the effect of absorbents (limestone or sodium bicarbonate), the kind and concentration of surfactants were assessed...

متن کامل

Assessing the Effectiveness of Sulfur Dioxide and Nitrogen Dioxide Pollutants due to Abadan Oil Refinery on Hospital Areas Using CALPUFF Model in 2018: A Descriptive Study

Background and Objectives: Hospitals as one of the most important sensitive populated areas must be located in areas within standard air quality. The aim of this study was assessing Abadan hospitals outdoor air quality affected by oil refinery using CALPUFF (California Puff) model. Materials and Methods: This descriptive study was performed on the dispersion of sulfur dioxide (SO2) and nitroge...

متن کامل

Status and prediction of sulfur dioxide as an air pollutant in the city of Ahvaz, Iran

The present research analyzes air quality in Ahvaz, a city in the south of Iran, paying special attention to sulfur dioxide (SO2). In order to prepare the average data in the city, measurements have been carried out between 2009 and 2010 in two different locations. Relations between sulfur dioxide and some meteorological parameters have been calculated statistically, using the daily average dat...

متن کامل

Status and prediction of sulfur dioxide as an air pollutant in the city of Ahvaz, Iran

The present research analyzes air quality in Ahvaz, a city in the south of Iran, paying special attention to sulfur dioxide (SO2). In order to prepare the average data in the city, measurements have been carried out between 2009 and 2010 in two different locations. Relations between sulfur dioxide and some meteorological parameters have been calculated statistically, using the daily average dat...

متن کامل

Gas/Liquid and Liquid/Liquid Solvent Extraction in Flow Analysis with the Chromatomembrane Cell

Since twelve years the Chromatomembrane Cell has been proposed as a new and versatile device for extraxtion procedures in the flow based analysis. In the meantime a remarkable number of papers was submitted dealing with applications of the novel method to all the conceivable varieties of flow injection and sequential injection analysis. The device supports important analytical procedures such a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2004