Asymmetric breast dose in coronary angiography
نویسندگان
چکیده
The purpose of this study was to demonstrate asymmetric radiation dose distribution to the breasts in coronary angiography. Gafchromic XR-QA2 film was used as an area dosimeter to capture the asymmetric dose distribution to the breasts at various tissue depths in an anthropomorphic phantom. A selection of tube angulations were used under a controlled experiment and during a mock coronary angiography procedure. The Gafchromic XR-QA2 film was able to confirm the asymmetric distribution of radiation dose to the breast and provide a normalized breast dose value. The right breast received the majority of dose for most of the tube angulations in the controlled experiment. However the left breast received the most radiation dose during the mock procedure. Asymmetric dose distribution to the breasts is normally not observed if Monte Carlo based simulations are performed because individual breast dose calculations are not available. The application of a typical coronary angiogram determined in the experiment showed the normalized left breast dose is 0.16 mGy/ Gy.cm2 and the right breast dose is 0.08 mGy/ Gy.cm2.
منابع مشابه
Breast Radiation Protection in Coronary Angiography
Introduction: Coronary angiography (CA) is an interventional diagnostic procedure to assess cardiovascular disease. CA is performed using dedicated fluoroscopic systems equipped with either flat detector or image intensifier. There is an increase in the number of CA annually. Reducing the radiation exposure in the CA is essential, especially due to high fluoroscopy time. In ord...
متن کاملEvaluation of cancer risk of the patients undergoing coronary angiography in Yazd, Iran
Background: Coronary angiography is a commonly performed diagnostic procedure with life saving benefits for the patient. However, this procedure involves relatively high radiation dose. The purpose of this study was to determine the average effective dose of patients undergoing coronary angiography and to estimate the associated radiation risk in terms of fatal malignancy. Materials an...
متن کاملAssessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)
Background: Practice of interventional cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with c...
متن کاملStaff dose assessment from coronary angiography
Background: Interventional cardiology procedures such as coronary angiography (CA) and percutaneous transluminal coronary angiography (PTCA) has been increased recent years. The purpose of this study was to measurement of effective dose to cardiology staffs who operate near the patient and are exposed to non-uniform radiation field due to patient scattered radiation. Materials and Methods: This...
متن کاملRadiation dose associated with coronary CT angiography and invasive coronary angiography: an experimental study of the effect of dose-saving strategies.
This study was conducted on a human anthropomorphic phantom to investigate the effective dose and entrance skin dose (ESD) in selected radiosensitive organs through invasive and computed tomography (CT) coronary angiography procedures using different dose-saving techniques. The effective dose was calculated as 2.49, 3.35 and 9.62 mSv, respectively, corresponding to three coronary CT angiography...