A headset-mounted mini sampler for measuring exposure to welding aerosol in the breathing zone.

نویسندگان

  • Göran Lidén
  • Jouni Surakka
چکیده

There is a need for a small personal aerosol sampler for measuring occupational exposure to airborne particles in the breathing zone. Existing aerosol samplers are too large to be mounted inside modern welder's protective equipment without disturbing the worker. A headset-mounted mini sampler has been developed to fill this gap with focus on manganese exposure. This mini sampler is easy to use and can be mounted inside modern, slimline welder's face shield. The mini sampler is based on a commercially available 13-mm filter holder that has been modified to incorporate an inlet nozzle made of aluminium. The nominal flow rate of the mini sampler is 0.75 l min(-1). The mini sampler is to be worn mounted on a headset, modified from professional microphone headsets. Several aspects related to using the mini sampler have been tested by personal and static sampling at five workplaces and in the laboratory. Four headset models were tested for their suitability as a sampler holder, of which three models were accepted by the welders. The sampling bias of the mini sampler versus the IOM sampler and the open-face 25-mm filter holder, respectively, depends on the size distribution of the sampled aerosol. At the lowest encountered mass concentration ratio of the open-face 25-mm filter holder to the IOM sampler (0.65), the sampling bias of the mini sampler versus the IOM sampler is approximately -26% and versus the open-face 25-mm filter holder is approximately +12%. For manganese, the negative root mean square (RMS) sampling bias of the mini sampler versus the IOM sampler is -0.046 and versus the open-face 25-mm filter holder is non-significant. Both these biases are statistically non-significant. The mini sampler can therefore be employed for determining welders' occupational exposure to manganese. The pressure drop across the filter can become excessive due to the small filtration area. Compared to the Casella Apex pump, the SKC AirChek2000 pump was generally found to be able to keep its flow rate constant within +/-5% at higher concentrations and for longer sampling times. Our results indicate that the inhalable fraction of the welding aerosol mass at the visited plants only consisted of 25-55% welding fume particles (agglomerates of coagulated particles generated by nucleation/condensation). The rest of the mass is made up of particles from spattering and grinding. More than 65% of manganese is generally found in the fume particles. The weighing precision of 13-mm filters is 2.2 microg. The RMS sample loss due to transport when loaded samples are shipped by mail in padded envelopes is 6 microg. Both figures are very low in comparison to the mass expected to be collected by personal sampling, generally exceeding 200 microg. The headset-mounted mini sampler is user-friendly, easy to adjust individually, does not disturb the welder during sampling and allows sampling inside personal protective equipment. The headset mounting arrangement improves personal sampling as it maintains the sampler close to the nose/mouth during the whole sampling period. This study shows that the developed headset-mounted mini sampler is suitable for assessing exposure to manganese in welding aerosol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of sampling positions when measuring personal exposure to solder fume.

A sampling device based on a telephone headset was developed and used to support a sampler close to the mouth during personal exposure monitoring of solder fume. In a field trial, it was compared with the established method of mounting the sampler on the arm of a pair of spectacles, and a linear correlation was evident between the two positions (slope 1.56 +/- 0.05, r(2) = 0.98). Although the h...

متن کامل

ارزیابی مقایسه ای مواجهه جوش‌کاران با فیوم‌های جوش‌کاری براساس تراکم جرمی و عددی

Introduction: Nowadays, Shielded Metal Arc Welding (SMAW) is the most widely used arc welding. During the welding operation, typically, various harmful agents such as fumes, gases, heat, sound and ultraviolet radiation are produced of which fume is the most important component from the viewpoint of occupational health. The present study aims to compare the number and the mass concentration emit...

متن کامل

Airborne Influenza A Is Detected in the Personal Breathing Zone of Swine Veterinarians

The 2009 H1N1 pandemic emphasized a need to evaluate zoonotic transmission of influenza A in swine production. Airborne influenza A virus has been detected in swine facilities during an outbreak. However, the personal exposure of veterinarians treating infected swine has not been characterized. Two personal bioaerosol samplers, the NIOSH bioaerosol sampler and the personal high-flow inhalable s...

متن کامل

Systemic inflammatory responses following welding inhalation challenge test

AIM The aim of this study was to investigate inflammatory and respiratory responses to welding fume exposure in patients with suspected occupational asthma. METHODS Sixteen patients referred to the Finnish Institute of Occupational Health underwent mild steel (MS) and stainless steel (SS) welding challenge tests, due to suspicion of OA. Platelet count, leucocytes and their differential count,...

متن کامل

Relation between various chromium compounds and some other elements in fumes from manual metal arc stainless steel welding.

For the years 1987-1990 160 individual samples of manual metal arc stainless steel (MMA/SS) welding fumes from the breathing zone of welders in four industrial plants were collected. Concentrations of soluble and insoluble chromium (Cr) III and Cr VI compounds as well as of some other welding fume elements (Fe, Mn, Ni, F) were determined. Concentration of welding fumes in the breathing zone ran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 53 2  شماره 

صفحات  -