Enhancement or reduction of sonochemical activity of pulsed ultrasound compared to continuous ultrasound at 20 kHz?

نویسندگان

  • Yujing Sun
  • Xingqian Ye
چکیده

Little is known about the efficacy of pulsed ultrasound compared with continuous ultrasound. Previous studies on the efficacy of pulsed ultrasound were not systematic and gave different results. In this study, the effects of pulse length, pulse interval, pulse length × pulse intervals, and treatment time on sonochemical activity were investigated using a simple oxidation of iodide method and a comparison of the efficacy of pulsed ultrasound and continuous ultrasound is made. The results showed that the main factor in the efficacy of pulsed ultrasound was pulse length when pulse length varied from 0.1 to 1 s. However, the main factors were pulse length, the pulse length × pulse interval, and pulse interval when pulse length varied from 1 to 9 s. Pulsed ultrasound had no effect when the pulse length was 0.1 s; however, the sonochemical activity of pulsed ultrasound decreased compared to continuous ultrasound as the pulse length varied from 0.1 to 1 s. The sonochemical activity of pulsed ultrasound either increased or decreased compared to continuous ultrasound when pulse length varied from 1 to 9 s, but the increase or decrease had no clear trend. The sonochemical activity was constant at T(on)/T(off) = 2 s/2 s and slightly decreased at T(on)/T(off) = 3 s/2 s with time, whereas the sonochemical activity of continuous ultrasound significantly decreased with time. Enhancement or reduction of sonochemical activity of pulsed ultrasound compared to continuous ultrasound depended on the pulse length and pulse interval.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Six Ultrasound Stimulation Types on Pseudomonas Aeruginosa Growth in Vitro

Background: This work evaluated the efficiency of common ultrasound stimulation (U.S.S) types on bacterial growth in vitro using clinically relevant conditions.Objective: To estimate different frequencies ultrasound bactericidal ability on bacteria in bacteria of Pseudomonas Aeruginosa. Methods: Six types of U.S.S (continuous wave, 7w/cm2, 20 KHz; continuous wave, 35w/0.8L, 40 KHz; continuous ...

متن کامل

The Effect of Bubble Surface Charge on Phonophoresis

It is over several decades that ultrasound is used to enhance the transdermal drug delivery (phonphoresis). The mechanism of the enhancement is not fully understood and the ability of ultrasound on the enhancement for some drugs is unclear. The effect of continuous wave 870 KHz ultrasound at intensity of 1 W/cm 2 for 15 minutes on transdermal absorption of piroxicam from solution and gel formu...

متن کامل

Evaluating the Effects of Dual Frequency Sonication Parameters on Acoustic Cavitation by Chemical Dosimeter Using Iodide

Background and Aims: Production of acoustic cavitation by sonication has been recently recommended as a targeted treatment. The experimental results from studies indicate that the activity of cavitation generated by bi- or multi-frequency ultrasound irradiation is higher than that caused by single frequency irradiation. In this study, effects dual (1 MHz and 40 kHz) and single frequency soni...

متن کامل

Modeling and Optimization of Ultrasound-Assisted Osmotic Dehydration with Finished Freeze Drying on Black Cherries – The Effect on Antioxidant Activities

ABSTRACT: In this study, response surface methodology was used to optimize ultrasound osmotic pretreatment with finished freeze drying of black cherries. Freeze drying is a separation process based on the  sublimation phenomenon. This process has the following advantages as compared to the conventional drying process, maintenance of the structure, moisture removal at low temperature (reduced tr...

متن کامل

Comparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma

Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecules

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2013