Digital Anatomical Measurement for Anterolateral Fixation of Middle and Lower Thoracic Vertebrae
نویسندگان
چکیده
BACKGROUND The key to its successful application is to determine the best entry point for the vertebral screw(s). This study aimed to provide a reference for clinical anterolateral fixation through digital measurement of computed tomography (CT) data to identify relevant anatomical positions in the middle and lower thoracic vertebrae (T4-T12) of 30 adults. MATERIAL AND METHODS We performed digital measurement of anatomical positions in the middle and lower thoracic vertebrae (T4-T12) of 30 adults. ABBREVIATIONS Left height of vertebral body, LHV; Right height of vertebral body, RHV; Anterior height of vertebral body, AHV; Middle height of vertebral body, MHV; Posterior height of vertebral body, PHV; Superior sagittal diameter of vertebral body, SSDV; Superior transverse diameter of vertebral body, STDV; inferior sagittal diameter of vertebral body, ISDV; Inferior transverse diameter of vertebral body, ITDV; (1) Left (right) height of vertebral body, [L(R)HV]; Anterior (middle, posterior) height of vertebral body [A(M,P)HV]; Superior (inferior) sagittal diameter of vertebral body, [S(I)SDV]; Superior (inferior) transverse diameter of vertebral body, [S(I)TDV]. RESULTS The transverse diameters of vertebral bodies were always larger than the sagittal diameter for 3~4 mm. The distance between 2 vertebrae (interval of 1 vertebra) range were (52-56) mm for T4-T7 and (44-48) mm for T8-T12, and the surgeons could collate these data to choose a suitable stick length. CONCLUSIONS Bone graft should prune into laterigrade cuboid, it can recover A-P and bilateral physiological functions load, and the height of the vertebral body increased from T4 to T12.
منابع مشابه
Late Onset of Thoracic Myelopathy with Type 2 Congenital Deformity: A Case Report
Background: Although there are several reports of paralysis developing after aggravation of the deformities of congenital kyphosis or kyphoscoliosis, the onset of myelopathy in middle-aged patients is rare. Objective: To describe a case of late onset thoracic myelopathy in a patient with anterolateral fused vertebrae. The progression of kyphoscoliosis in this middle-aged patient preceded the on...
متن کاملEvaluation of Neurovascular Complication of Cervical Ribs
Introduction: Cervical rib is relatively uncommon congenital abnormality that originates from the seventh cervical vertebrae and rarely from the sixth vertebrae. The purpose of this paper is to consider that this abnormal condition is an important cause of neurovascular compression at the thoracic outlet. Methods: In this study all patients who were referred to radiology departm...
متن کاملمقایسه تفاوت لندمارک های آناتومیک دو تکنیک رادیوگرافی لترال سفالومتری دیجیتال و معمولی به روش ترسیم دستی در جمجمه های انسانی
Background and purpose: Digital radiography has led to many improvements in radiology. Despite many advantages there are different ideas in determining anatomical landmarks which results in some errors in cephalometric analyses. The aim of this study was to determine the degree of identification differences of anatomical landmarks by conventional and digital lateral cephalometric techniques usi...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملLoad sharing within a human thoracic vertebral body: an in vitro biomechanical study.
OBJECTIVE The vertebral body is the major load bearing part of the vertebra and consists of a central trabecular core surrounded by a thin cortical shell. The aim of this in vitro biomechanical study is to determine the debated issue of load sharing in a vertebral body. METHODS A series of non-destructive compressive testing on excised human thoracic vertebral bodies were performed. The testi...
متن کامل