Integral-based filtering of continuous glucose sensor measurements for glycaemic control in critical care

نویسندگان

  • J. Geoffrey Chase
  • Christopher E. Hann
  • Monique Jackson
  • Jessica Lin
  • Thomas Lotz
  • Xing-Wei Wong
  • Geoffrey M. Shaw
چکیده

Hyperglycaemia is prevalent in critical illness and increases the risk of further complications and mortality, while tight control can reduce mortality up to 43%. Adaptive control methods are capable of highly accurate, targeted blood glucose regulation using limited numbers of manual measurements due to patient discomfort and labour intensity. Therefore, the option to obtain greater data density using emerging continuous glucose sensing devices is attractive. However, the few such systems currently available can have errors in excess of 20-30%. In contrast, typical bedside testing kits have errors of approximately 7-10%. Despite greater measurement frequency larger errors significantly impact the resulting glucose and patient specific parameter estimates, and thus the control actions determined creating an important safety and performance issue. This paper models the impact of the continuous glucose monitoring system (CGMS, Medtronic, Northridge, CA) on model-based parameter identification and glucose prediction. An integral-based fitting and filtering method is developed to reduce the effect of these errors. A noise model is developed based on CGMS data reported in the literature, and is slightly conservative with a mean Clarke Error Grid (CEG) correlation of R=0.81 (range: 0.68-0.88) as compared to a reported value of R=0.82 in a critical care study. Using 17 virtual patient profiles developed from retrospective clinical data, this noise model was used to test the methods developed. Monte-Carlo simulation for each patient resulted in an average absolute 1-h glucose prediction error of 6.20% (range: 4.97-8.06%) with an average standard deviation per patient of 5.22% (range: 3.26-8.55%). Note that all the methods and results are generalizable to similar applications outside of critical care, such as less acute wards and eventually ambulatory individuals. Clinically, the results show one possible computational method for managing the larger errors encountered in emerging continuous blood glucose sensors, thus enabling their more effective use in clinical glucose regulation studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using Stochastic modelling to identify unusual continuous glucose monitor measurements and behaviour, in newborn infants

BACKGROUND Abnormal blood glucose (BG) concentrations have been associated with increased morbidity and mortality in both critically ill adults and infants. Furthermore, hypoglycaemia and glycaemic variability have both been independently linked to mortality in these patients. Continuous Glucose Monitoring (CGM) devices have the potential to improve detection and diagnosis of these glycaemic ab...

متن کامل

Tight glycaemic control: a prospective observational study of a computerised decision-supported intensive insulin therapy protocol

INTRODUCTION A single centre has reported that implementation of an intensive insulin protocol, aiming for tight glycaemic control (blood glucose 4.4 to 6.1 mmol/l), resulted in significant reduction in mortality in longer stay medical and surgical critically ill patients. Our aim was to determine the degree to which tight glycaemic control can be maintained using an intensive insulin therapy p...

متن کامل

Continuous glucose sensors for glycaemic control in the ICU: have we arrived?

Dr Blixt and colleagues show in an elegant pilot study that the continuous measurement of glucose in venous blood by microdialysis in a central venous catheter is feasible in critically ill patients. The performance of this type of continuous glucose monitoring device equals the performance of the commonly used handheld blood glucose meters. But are we, as ICU physicians and nurses, now ready t...

متن کامل

Rethinking glycaemic control in critical illness--from concept to clinical practice change.

OBJECTIVE To examine the practical difficulties in managing hyperglycaemia in critical illness and to present recently developed model-based glycaemic management protocols to provide tight control. BACKGROUND Hyperglycaemia is prevalent in critical care. Current published protocols require significant added clinical effort and have highly variable results. No currently published methods succe...

متن کامل

Enteral nutrition versus glucose-based or lipid-based parenteral nutrition and tight glycaemic control in critically ill patients.

OBJECTIVE Early administration of nutrition and attention to tight glycaemic control are both associated with improved outcomes in critically ill patients. We hypothesized that blood glucose control would be better achieved in patients receiving enteral rather than parenteral nutrition and, in the latter group, would be better achieved using a "balanced" glucose plus lipid solution than a dextr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods and programs in biomedicine

دوره 82 3  شماره 

صفحات  -