Differences in aerodynamic particle size distributions of innovator and generic beclomethasone dipropionate aerosols used with and without a large volume spacer.
نویسندگان
چکیده
BACKGROUND The equivalence of generic beclomethasone dipropionate (BDP) formulations with their innovator counterpart must be demonstrated if generic formulations are to be used. This study has examined the aerodynamic particle size distributions of both innovator and generic formulations of BDP and the effect of a large volume spacer (Volumatic) on these distributions. METHODS Aerosol clouds of three formulations of BDP delivering 250 micrograms per metered dose were characterised using a high precision multistage liquid impinger, and the amount of drug in different particle size bands was determined by spectrophotometric assay. RESULTS The mean (SD) respirable fractions of Becloforte, Beclazone, and Filair without the spacer (n = 10) were 24.1 (2.1)%, 23.1 (2.7)%, and 23.0 (2.1)% respectively; however, the ratio of deposition on stage 4 of the impinger to that on stage 3 was lower for Beclazone and for Filair than for Becloforte, implying a smaller proportion of fine particles for the generic products. When the three products delivered via the Volumatic spacer device were compared, the respirable fraction for Becloforte (n = 10) was 25.0 (4.0)%, but those of Beclazone (n = 10) and Filair (n = 11) were 16.0 (1.9)% and 14.6 (3.4)%. Repeat testing (n = 5) at a later date showed higher mean respirable fractions for all three products, but a trend towards the highest respirable fraction for Becloforte, and the same rank order for the other two products. CONCLUSIONS These in vitro findings suggest that the particle size distributions of the two generic formulations of BDP are not equivalent to that of the innovator product. Some differences in particle size distributions might not have been detected by a twin impinger. Clinical testing would be required to assess the therapeutic equivalence of innovator and generic corticosteroid products used with or without spacer devices.
منابع مشابه
Systemic effects of high dose inhaled steroids: comparison of beclomethasone dipropionate and budesonide in healthy subjects.
BACKGROUND Systemic absorption of inhaled corticosteroids may adversely influence the function of the hypothalamo-pituitary-adrenal axis, bone metabolism, and circulating leucocytes. These changes can be used to assess the safety of different types and modes of administration of these drugs. METHODS The study was a randomised, double dummy, crossover design with nine healthy adults. It compar...
متن کاملThe effects of inhaled beclomethasone dipropionate on lung function and histamine responsiveness in recurrently wheezy infants.
Inhaled steroids improve pulmonary function and bronchial responsiveness in older asthmatics. Data from studies using subjective outcome measures to determine the effectiveness of inhaled steroids in infants with recurrent wheezing are equivocal. Therefore, this study tested the hypothesis that beclomethasone dipropionate improves pulmonary function, including bronchial responsiveness to histam...
متن کاملSystemic activity of inhaled and swallowed beclomethasone dipropionate and the effect of different inhaler devices.
Inhaled glucocorticoids such as beclomethasone dipropionate, which are used in the treatment of asthma, may be associated with systemic adverse effects. To determine whether any systemic absorption following the inhalation of beclomethasone was a result of drug being absorbed from the lung (inhaled fraction) or the gastrointestinal tract (swallowed fraction), we studied normal subjects after th...
متن کاملParticle size of beclomethasone dipropionate produced by two nebulisers and two spacing devices.
An impactor method was used to assess the amount of beclomethasone dipropionate in particles less than 5 microns produced by two nebulisers (Pari Inhalierboy, Medix Traveller compressor with cirrhus nebuliser chamber) and two spacer devices (Volumatic and Nebuhaler). After nebulisation of 3 ml (150 micrograms) beclomethasone dipropionate the amount of drug in particles less than 5 microns was 1...
متن کاملLarge volume spacer devices and the influence of high dose beclomethasone dipropionate on hypothalamo-pituitary-adrenal axis function.
BACKGROUND The systemic effects of the inhaled corticosteroid beclomethasone dipropionate are reduced if the drug is inhaled through a large volume spacer. Use of spacers may therefore permit higher doses to be given without causing hypothalamo-pituitary-adrenal suppression. METHODS Randomised, double blind, double dummy, parallel group study was carried out in adults with chronic asthma to d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 50 8 شماره
صفحات -
تاریخ انتشار 1995