Gastric accommodation and motility are influenced by the barostat device: Assessment with magnetic resonance imaging.
نویسندگان
چکیده
The barostat is considered the gold standard for evaluation of proximal gastric motility especially for the accommodation response to a meal. The procedure is invasive because it involves the introduction of an intragastric catheter and bag and is not always well tolerated. Moreover, the barostat bag itself may influence motility. Nowadays magnetic resonance imaging (MRI) is able to measure several aspects of gastric motility noninvasively. To evaluate whether the accommodation response of the stomach, observed with the barostat, is present during MRI and whether the barostat interferes with gastric physiology, gastric accommodation, motility, and emptying were studied twice in 14 healthy subjects with MRI using three-dimensional volume scans and two-dimensional dynamic scans once in the presence of a barostat bag and once when the barostat bag was not present. Fasting and postprandial intragastric volumes were significantly higher in the experiment with barostat vs. without barostat (fasting: 350 +/- 132 ml vs. 37 +/- 21 ml, P < 0.0001; postprandial: 852 +/- 126 ml vs. 361 +/- 62 ml, P < 0.0001). No significant differences were found in gastric emptying (88 +/- 41 vs. 97 +/- 40 ml/h, not significant) and contraction frequency between both experiments. The accommodation response observed in the presence of the barostat bag was not observed in the absence of the barostat bag. In conclusion, the presence of an intragastric barostat bag does not interfere with gastric emptying or motility, but the accommodation response measured with the barostat in situ is not observed without the barostat bag in situ. Gastric accommodation is a nonphysiological barostat-induced phenomenon.
منابع مشابه
Running head: Gastric accommodation and motility by MRI and barostat
Background: The barostat is considered the gold standard for evaluation of proximal gastric motility especially for the accommodation response to a meal. The procedure is invasive because it involves the introduction of an intragastric catheter and bag and is not always well tolerated. Moreover, the barostat bag itself may influence motility. Nowadays Magnetic Resonance Imaging (MRI) is able to...
متن کاملCharacterization of gastric volume responses and liquid emptying in functional dyspepsia and health by MRI or barostat and simultaneous C-acetate breath test.
The assessment of gastric accommodation and emptying by different methodologies provides inconsistent results. We aimed to compare magnetic resonance imaging (MRI), barostat and 13C-acetate breath test (BT) for the assessment of gastric volume responses and emptying in healthy controls (HC) and patients with functional dyspepsia (FD). Eight HC and eight FD patients underwent: (i) continuous BT ...
متن کاملAssessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques
The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...
متن کاملThe modeling of induced current density in eyes from static magnetic fields produce by MR scanner
Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...
متن کاملThe Assessment of Toxicity Characteristics of Cellular Uptake of Paramagnetic Nanoparticles as a New Magnetic Resonance Imaging Contrast Agent
Nanoparticles are unique that enable many promising medical and technological applications intheir physical, and chemical properties. It is widely accepted that nanoparticles should bethoroughly tested for health nanotoxicity, but a moderate risk analysis is currently prevented by arevealing absence of mechanistic knowledge of nanoparticle toxicity. The purpose of this study<b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Gastrointestinal and liver physiology
دوره 292 1 شماره
صفحات -
تاریخ انتشار 2007