Comparison of a nonradiometric liquid-medium method (MB REDOX) with the BACTEC system for growth and identification of mycobacteria in clinical specimens.

نویسندگان

  • Y C Liu
  • T S Huang
  • W K Huang
چکیده

Early identification of tuberculosis in the clinical setting is of great importance in order for specific therapy to be swiftly initiated. MB REDOX (Heipha Diagnostika), a growth-based medium without radioactive materials, was evaluated and was compared to the BACTEC system for detection of mycobacteria, including the Mycobacterium tuberculosis complex and atypical mycobacteria. MB REDOX consists of a Kirchner medium enriched with growth-promoting additives, antibiotic compounds, and a redox indicator which can be monitored to detect growth of mycobacteria with the naked eye. MB REDOX only detects growth and cannot differentiate the M. tuberculosis complex (M. tuberculosis, M. bovis, and M. africanum) from other species of Mycobacterium. Therefore, PCR-restriction fragment length polymorphism analysis (PRA) was used in this investigation to identify to the species level organisms showing positive growth with MB REDOX. Our data demonstrate the usefulness of MB REDOX for the detection of mycobacteria in clinical specimens. The rate of detection of M. tuberculosis complex with MB REDOX (84. 3%) was higher than that with the BACTEC system (68.6%). When combined with PRA for species identification, MB REDOX is easy to perform and is suited to most clinical laboratory settings for the detection and identification of mycobacteria.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two liquid medium systems, mycobacteria growth indicator tube and MB redox tube, for Mycobacterium tuberculosis isolation from sputum specimens.

Two manual liquid medium systems, the Mycobacteria Growth Indicator Tube (MGIT) and MB Redox tube systems, were evaluated in comparison to the radiometric BACTEC-460 semiautomated system for recovery of Mycobacterium tuberculosis from sputum specimens. The highest level of recovery, from a total of 77 culture-positive specimens, occurred with the BACTEC-460 system (92.2%), followed by the MB Re...

متن کامل

Comparison of the MB/BacT and BACTEC 460 TB systems for recovery of mycobacteria from various clinical specimens.

A total of 1,830 specimens (75.7% respiratory and 24.3% nonrespiratory) were cultured in parallel with the MB/BacT and BACTEC 460 TB systems and on Lowenstein-Jensen (LJ) medium. Mycobacteria were identified from 173 (6.5%) specimens. The most common species recovered were Mycobacterium tuberculosis complex (65. 9%), Mycobacterium avium complex (22.5%), and Mycobacterium chelonae (9.2%). The re...

متن کامل

Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium.

Using two different liquid media and one conventional solid medium, a total of 57 mycobacterial isolates (Mycobacterium tuberculosis, n = 55; nontuberculous mycobacteria, n = 2) were recovered from 377 clinical specimens. The rates of recovery of M. tuberculosis were 96. 4% with the BACTEC MGIT 960 liquid medium, 92.7% with BACTEC 12B liquid medium, and 81.8% with the Löwenstein-Jensen (LJ) med...

متن کامل

Evaluation of the BACTEC MGIT 960 and the MB/BacT systems for recovery of mycobacteria from clinical specimens and for species identification by DNA AccuProbe.

A total of 120 mycobacterial isolates were recovered from 1,068 clinical specimens. Of these, 82.5% were in MGIT 960, 83.3% were in MB/BacT, 80% were in BACTEC 460, and 70% were on Löwenstein-Jensen medium. Mean times to detection of Mycobacterium tuberculosis (n = 96) were significantly shorter with MGIT 960 (12.6 days, P = 0.003) and BACTEC 460 (11.8 days, P < 0.001) than with MB/BacT (15.9 d...

متن کامل

[Comparison of MB-Check, BACTEC, and egg-based media for recovery of mycobacteria].

The rate of recovery and time to the detection of mycobacteria from clinical specimens were measured for biphasic and radiometric liquid-based culture systems and egg-based media (3% Ogawa and Ogawa K). From the 245 sputum specimens processed, a total of 86 (35.1%) mycobacterial isolates were detected. Of these, 81 (94.2%) and 80 (93.0%) isolates were detected with the MB-Check and BACTEC syste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 12  شماره 

صفحات  -

تاریخ انتشار 1999