Study of DQE dependence with beam quality on GE Essential mammography flat panel
نویسندگان
چکیده
This paper deals with the analysis of the behavior of objective image quality parameters for the new GE Senographe Essential FFDM system, in particular its dependence with beam quality. The detector consists of an indirect conversion a-Si flat panel coupled to a CsI:Tl scintillator. The system under study has gone through a series of relevant modifications in flat panel with respect to the previous model (GE Senographe DS 2000). These changes in the detector modify its performance and are intended to favor advanced applications like tomosynthesis, which uses harder beam spectra and lower doses per exposure than conventional FFDM. Although our system does not have tomosynthesis implemented, we noticed that most clinical explorations were performed by automatically selecting a harder spectrum than that of typical use in FFDM (Rh/Rh 28-30 kV instead of Mo/Mo 28 kV). Since flat-panel optimization for tomosynthesis influences the usual FFDM clinical performance, the new detector behavior needed to be investigated. Therefore, the aim of our study is evaluating the dependence of the detector performance for different beam spectra and exposure levels. In this way, we covered the clinical beam quality range (Rh/Rh 28-30 kV) and we extended the study to even harder spectra (Rh/Rh 34 kV). Detector performance is quantified by means of modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). We found that flat-panel optimization results in slightly - but statistically significant - higher DQE values as beam quality increases, which is contrary to the expected behavior. This positive correlation between beam quality and DQE is also diametrically opposite to that of the previous model by the same manufacturer. As a direct consequence, usual FFDM takes advantage of the changes in the detector, as less exposure is needed to achieve the same DQE if harder beams are used.
منابع مشابه
Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).
A theoretical method is presented that allows identification of optimal x-ray imaging geometry, considering the effects of x-ray source distribution, imaging task, x-ray scatter, and imager detective quantum efficiency (DQE). Each of these factors is incorporated into the ICRU-recommended figure of merit for image quality, the detectability index, which is maximized to determine the optimal sys...
متن کاملThree-Dimensional NEQ Transfer Characteristics of Volume CT using Direct and Indirect-Detection Flat-Panel Imagers
Foremost among the promising imaging performance characteristics of cone-beam CT using flat-panel imagers is the ability to form volumetric images with soft-tissue contrast visibility in combination with sub-millimeter 3-D spatial resolution. Each of these two essential characteristics is intimately related to the spatial-frequency-dependent signal and noise transfer characteristics of the imag...
متن کاملQuantitative image quality measurements of a digital breast tomosynthesis system.
PURPOSE The aim of this study was to measure the image quality of a digital breast tomosynthesis (DBT) system quantitatively. MATERIALS AND METHODS The signal transfer property (STP), modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) of the Hologic Selenia Dimensions breast tomosynthesis system were measured according to established methods...
متن کاملComparison of different commercial FFDM units by means of physical characterization and contrast-detail analysis.
The purpose of this study was to perform a complete evaluation of three pieces of clinical digital mammography equipment. Image quality was assessed by performing physical characterization and contrast-detail (CD) analysis. We considered three different FFDM systems: a computed radiography unit (Fuji "FCR 5000 MA") and two flat-panel units, the indirect conversion a-Si based GE "Senographe 2000...
متن کاملPractical expressions describing detective quantum efficiency in flat-panel detectors
In radiology, image quality excellence is a balance between system performance and patient dose, hence x-ray systems must be designed to ensure the maximum image quality is obtained for the lowest consistent dose. The concept of detective quantum efficiency (DQE) is widely used to quantify, understand, measure, and predict the performance of x-ray detectors and imaging systems. Cascaded linear-...