Quantification and compensation of eddy-current-induced magnetic-field gradients.

نویسندگان

  • William M Spees
  • Niels Buhl
  • Peng Sun
  • Joseph J H Ackerman
  • Jeffrey J Neil
  • Joel R Garbow
چکیده

Two robust techniques for quantification and compensation of eddy-current-induced magnetic-field gradients and static magnetic-field shifts (ΔB0) in MRI systems are described. Purpose-built 1-D or six-point phantoms are employed. Both procedures involve measuring the effects of a prior magnetic-field-gradient test pulse on the phantom's free induction decay (FID). Phantom-specific analysis of the resulting FID data produces estimates of the time-dependent, eddy-current-induced magnetic field gradient(s) and ΔB0 shift. Using Bayesian methods, the time dependencies of the eddy-current-induced decays are modeled as sums of exponentially decaying components, each defined by an amplitude and time constant. These amplitudes and time constants are employed to adjust the scanner's gradient pre-emphasis unit and eliminate undesirable eddy-current effects. Measurement with the six-point sample phantom allows for simultaneous, direct estimation of both on-axis and cross-term eddy-current-induced gradients. The two methods are demonstrated and validated on several MRI systems with actively-shielded gradient coil sets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Localized eddy current compensation using quantitative field mapping.

Eddy current effects induced by switched gradients in proximal conducting structures are traditionally reduced by applying preemphasis currents whose amplitudes and decay characteristics must be set to offset the eddy current fields. We present an expeditious, localized, and quantitative method for mapping and adjusting the parameters for eddy current compensation. Mapping is based on analysis ...

متن کامل

Analysis of the eddy-current induced artifacts and the temporal compensation in nuclear magnetic resonance imaging.

Reduction of eddy currents by a temporal compensation of the input current waveform to the gradient coil is studied with an analytic solution. The technique is the inverse filtering of the eddy-current affected field response, which is calculated from the diffusion equation. The limitation of the temporal compensation due to the spatially variant eddy currents is also investigated for whole-bod...

متن کامل

Spatial detection of ferromagnetic wires using GMR sensor and based on shape induced anisotropy

The purpose of this paper is to introduce a new technique for row spacing measurement in a wire array using giant magnetoresistive (GMR) sensor. The self-rectifying property of the GMR-based probes leads to accurately detection of the magnetic field fluctuations caused by surface-breaking cracks in conductive materials, shape-induced magnetic anisotropy, etc. The ability to manufacture probes h...

متن کامل

Effect of Vacuum Chamber Eddy Current and Compensation by Digital Feedback

Measurement of the effect of the eddy current induced in the APS storage ring vacuum chamber by the storage ring sextupole magnet and its compensation using digital feedback with proportional, integral, and derivative (PID) control algorithm are presented. The magnetic field in the vacuum chamber shows strong quadrupole and sextupole components varying with frequency, in addition to significant...

متن کامل

Can we re-design the gradient coil to make the eddy current field match the primary gradient field?

Introduction: Rapidly switched magnetic field gradients induce eddy currents in the nearby conducting structures of the MRI scanner. These eddy currents in turn generate an opposing and distorting transient magnetic field in the region of interest (ROI) with consequential image distortion. A tailored current pulse is usually applied to minimize the undesired effects of the eddy currents in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 212 1  شماره 

صفحات  -

تاریخ انتشار 2011