Clinical study of the sensitivity and dynamic range of three digital systems, E-speed film and digitized film.

نویسندگان

  • F N Bóscolo
  • A E Oliveira
  • S M Almeida
  • C F Haiter
  • F Haiter Neto
چکیده

The objective of the present study was to clinically evaluate the sensitivity and dynamic range of three digital systems (Sens-A-Ray, CDR, Digora), digitized film and E-speed film. Five objects were submitted to three different kilovoltages and seven exposure times. In order to evaluate the relationship between exposure time and dosage, measurements were made in a dental x-ray unit with an ion chamber, X-ray timer and kVp meter. For each system, 105 radiographs were taken, totalling 525 images, that were evaluated by six trained observers by means of scoring from 0 to 4. The scores attributed to the images for each of the systems were submitted to analysis of variance and Turkey's test. The results showed statistically significant differences (p < 0.01) with the storage phosphor system producing the wider dynamic range, followed by the digitized film. The CDR system showed the greater sensitivity, followed by the Digora system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه دقت تصاویر رادیوگرافی

Statement of Problem: Computer Sciences, in radiology, like other fields, is of high importance. It should also be noted that the accuracy of the technique and work conditions affects the radiographs information considerably. There for, in order to get more accurate diagnostic information, it seems necessary to investigate different digitized radiographic techniques and to compare them with the...

متن کامل

The perceptibility curve test applied to CCD and two methods of digitization of dental film-based radiographs

Objectives: Several methods of image acquisition are accessible in dentistry. There is no overall acceptable method for image digitization so all different types of images can be comparable. The objective of this study was to compare the diagnostic accuracy of different methods of image digitization. Methods: This accuracy diagnostic test study used perceptibility curve test which first intr...

متن کامل

Sensitometric characteristics of D-, E- and F-speed dental radiographic films in manual and automatic processing

BACKGROUND: The purpose of this study was to evaluate the sensitometric characteristics of Ultraspeed, Ektaspeed Plus and Insight dental radiographic films using manual and automatic processing systems. METHODS: In this experimental invitro study, an aluminum step-wedge was used to construct characteristic curves for D-, E- and F-speed radiographic films (Kodak Eastman, Rochester, USA). All fil...

متن کامل

In vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection

Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im‌age quality and elimination of processing, it has been extensively used in different fields of denti‌stry in recent years. The purpose of this study wa...

متن کامل

A study of densitometry comparison among three radiographic processing solutions

ABSTRACT Background: The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and process...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 2001