Reference-based linear curve fitting for bolus arrival time estimation in 4D MRA and MR perfusion-weighted image sequences.

نویسندگان

  • Nils Daniel Forkert
  • Jens Fiehler
  • Thorsten Ries
  • Till Illies
  • Dietmar Möller
  • Heinz Handels
  • Dennis Säring
چکیده

The bolus arrival time (BAT) based on an indicator dilution curve is an important hemodynamic parameter. As the direct estimation of this parameter is generally problematic, various parametric models have been proposed that describe typical physiological shapes of indicator dilution curves, but it remains unclear which model describes the real physiological background. This article presents a method that indirectly incorporates physiological information derived from the data available. For this, a patient-specific hemodynamic reference curve is extracted, and the corresponding reference BAT is determined. To estimate a BAT for a given signal curve, the reference curve is fitted linearly to the signal curve. The parameters of the fitting process are then used to transfer the reference BAT to the signal curve. The validation of the method proposed based on Monte Carlo simulations showed that the approach presented is capable of improving the BAT estimation precision compared with standard BAT estimation methods by up to 59% while at the same time reduces the computation time. A major benefit of the method proposed is that no assumption about the underlying distribution of indicator dilution has to be made, as it is implicitly modeled in the reference curve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-resolved MRA from head to toe – nice toy or helpful clinical tool?

Time-resolved MR angiography (MRA) has been proposed as a non-invasive and nonionizing imaging method. Compared with monophasic CTA and MRA it provides better arteriovenous differentiation and functional dynamic information that so far has been gained only with DSA. When contrast-enhanced MRA was first introduced in 1993 acquisition time was in the range of several minutes. In addition the imag...

متن کامل

A PRACTICAL APPROACH TO REAL-TIME DYNAMIC BACKGROUND GENERATION BASED ON A TEMPORAL MEDIAN FILTER

In many computer vision applications, segmenting and extraction of moving objects in video sequences is an essential task. Background subtraction, by which each input image is subtracted from the reference image, has often been used for this purpose. In this paper, we offer a novel background-subtraction technique for real-time dynamic background generation using color images that are taken fro...

متن کامل

Visualization and Analysis of Cerebral Arteriovenous Malformation combining 3D and 4D MR Image Sequences

In this paper methods for visualization and analysis of cerebral arteriovenous malformations (AVM) are presented. Spatiotemporal 4D magnetic resonance angiography (MRA) image datasets and 3D MRA datasets with high spatial resolution were acquired for analyzing AVMs. One of the main tasks is the combination of the information of these 3D and 4D MRA image sequences. Initially, in the 3D MRA datas...

متن کامل

Cardiovascular magnetic resonance physics for clinicians: part II

This is the second of two reviews that is intended to cover the essential aspects of cardiovascular magnetic resonance (CMR) physics in a way that is understandable and relevant to clinicians using CMR in their daily practice. Starting with the basic pulse sequences and contrast mechanisms described in part I, it briefly discusses further approaches to accelerate image acquisition. It then cont...

متن کامل

High-resolution dynamic CE-MRA of the thorax enabled by iterative TWIST reconstruction.

PURPOSE To evaluate the clinical benefit of using a new iterative reconstruction technique fully integrated on a standard clinical scanner and reconstruction system using a TWIST acquisition for high-resolution dynamic three-dimensional contrast-enhanced MR angiography (CE-MRA). METHODS Low-dose, high-resolution TWIST datasets of 11 patients were reconstructed using both standard GRAPPA-based...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 65 1  شماره 

صفحات  -

تاریخ انتشار 2011