Endodontic rotary nickel-titanium instrument systems.PDF

نویسندگان

  • Brent J. Crumpton
  • Scott McClanahan
چکیده

Since the end of the nineteenth century, automated root canal instrumentation has been available, but systems had many problems. The challenges of increased canal blockage, instrument breakage, and insufficient canal debridement were related to the use of stainless steel instruments and have been dramatically improved with the introduction of nickel-titanium (NiTi) files. The first useable NiTi alloy was developed by William Buehler in 1960 at the U. S. Navy Ordinance Lab in Silver Spring, Maryland. Walia et al. investigated the feasibility of using this alloy in the fabrication of endodontic files, and showed that NiTi files had two to three times the elastic flexibility in bending and torsion, as well as superior resistance to torsional fracture when compared with stainless steel files of the same size. These features led to better centering of the instruments within the canal (1), less straightening of the canal, fewer elbows and ledges, and less transportation (2).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A dozen ways to prevent nickel-titanium rotary instrument fracture.

BACKGROUND and Overview. With the increased use of nickel-titanium (NiTi) rotary instruments for root canal preparation in endodontics, instrument fracture has become more prevalent. Extensive research has been conducted on the physical properties and mechanical characteristics of NiTi rotary instruments, as well as the factors that can contribute to instrument failure. NiTi rotary instruments ...

متن کامل

Predicting in vivo failure of rotary nickel-titanium endodontic instruments under cyclic fatigue.

The aim of this study was to examine the lifespan or number of cycles to failure of tapered rotary nickel-titanium (Ni-Ti) endodontic instruments. Simulated root canals with different curvatures were used to determine a relation between canal curvature and instrument lifespan. Using a novel mathematical model for the deformation of pseudoelastic Ni-Ti alloy, it was shown that maximum stress nee...

متن کامل

Problems with a Cordless Endodontic Hand Piece when Preparing Severely Curved Root Canals

Successful endodontic treatment mainly relies on preserving the original anatomy of the root canal while avoiding instrument fractures and iatrogenic preparation errors, such as loss of working length, zipping, or ledging [1,2]. In most cases, rotary instrumentation has proved a valuable advancement for meeting these parameters. Unlike stainless steel files, nickel-titanium instruments have suf...

متن کامل

Rationale for the use of low-torque endodontic motors in root canal instrumentation.

Fracture of nickel-titanium rotary files is an iatrogenic error which can seriously jeopardize root canal therapy. If a high-torque motor is used, the instrument-specific limit-torque (fracture limit) is often exceeded, thus increasing the risk of intracanal failure. A possible solution to this problem is to use a low-torque endodontic motor which operates below these values. If the torque is s...

متن کامل

Current Strategies in Metallurgical Advances of Rotary NiTi Instruments: A Review

NiTi alloy has been used as the raw material for making endodontic files. The interest in NiTi instrument research has not waned with time. In fact, there is a renewed interest in this field, notably through the application of modern research tools and techniques from other fields, making it a truly cross-disciplinary area of research. In 1988, Walia and colleagues introduced nickeltitanium (Ni...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006