Artifact removal in photoacoustic section imaging by combining an integrating cylindrical detector with model-based reconstruction.

نویسندگان

  • Guenther Paltauf
  • Robert Nuster
چکیده

Photoacoustic section imaging reveals optically absorbing structures within a thin slice of an object. It requires measuring acoustic waves excited by absorption of short laser pulses with a cylindrical acoustic lens detector rotating around the object. Owing to the finite detector size and its limited depth of focus, various artifacts arise, seen as distortions within the imaging slice and cross-talk from neighboring areas of the object. The presented solution aims at avoiding these artifacts by a special design of the sensor and by use of a model-based reconstruction algorithm that improves section images by incorporating information from neighboring sections. The integrating property of the cylindrical detector, which exceeds in direction of the cylinder axis the size of the imaged object, avoids the lateral blurring that normally results from the finite width of a small detector. Applying a maximum likelihood reconstruction method for the inversion of the imaging system matrix to the temporal pressure signals yields line projections of the initial energy distribution, from which section images are obtained by applying the inverse Radon transform. By using data from few sections, a significant reduction of artifacts related to the imperfections of the sensor is demonstrated both in simulations and in phantom experiments.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoacoustic section imaging with an integrating cylindrical detector

A piezoelectric detector with a cylindrical shape is investigated for photoacoustic section imaging. Images are acquired by rotating a sample in front of the cylindrical detector. With its length exceeding the size of the imaging object, it works as an integrating sensor and therefore allows reconstructing section images with the inverse Radon transform. Prior to the reconstruction the Abel tra...

متن کامل

Photoacoustic Section Imaging with Integrating Detectors

Photoacoustic section imaging is a method for visualizing structures with optical contrast in selected layers of an extended object. In order to avoid resolution limitations that are due to commonly used ultrasound detectors of finite size, we propose the use of extended, integrating cylindrical elements for focusing the acoustic detection into the selected section. Two imaging methods based on...

متن کامل

Collimator-detector response compensation in molecular SPECT reconstruction using STIR framework

Introduction:It is well-recognized that collimator-detector response (CDR) is the main image blurring factor in SPECT.  In this research, we compensated the images for CDR in molecular SPECT by using STIR reconstruction framework. Methods: To assess resolution recovery capability of the STIR, a phantom containing five point sources along with a micro Derenzo p...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Piezoelectric line detector array for photoacoustic tomography

Photoacoustic tomography relies on a dense coverage of the surface surrounding the imaged object with ultrasound sensors in order to enable an accurate reconstruction. A curved arrangement of integrating line sensors is proposed that is able to acquire data for a linear projection image of the absorbed energy density distribution in the object. Upon rotation of the object relative to the array,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2014