Deformation correction for image guided liver surgery: An intraoperative fidelity assessment.

نویسندگان

  • Logan W Clements
  • Jarrod A Collins
  • Jared A Weis
  • Amber L Simpson
  • T Peter Kingham
  • William R Jarnagin
  • Michael I Miga
چکیده

BACKGROUND Although systems of 3-dimensional image-guided surgery are a valuable adjunct across numerous procedures, differences in organ shape between that reflected in the preoperative image data and the intraoperative state can compromise the fidelity of such guidance based on the image. In this work, we assessed in real time a novel, 3-dimensional image-guided operation platform that incorporates soft tissue deformation. METHODS A series of 125 alignment evaluations were performed across 20 patients. During the operation, the surgeon assessed the liver by swabbing an optically tracked stylus over the liver surface and viewing the image-guided operation display. Each patient had approximately 6 intraoperative comparative evaluations. For each assessment, 1 of only 2 types of alignments were considered: conventional rigid and novel deformable. The series of alignment types used was randomized and blinded to the surgeon. The surgeon provided a rating, R, from -3 to +3 for each display compared with the previous display, whereby a negative rating indicated degradation in fidelity and a positive rating an improvement. RESULTS A statistical analysis of the series of rating data by the clinician indicated that the surgeons were able to perceive an improvement (defined as a R > 1) of the model-based registration over the rigid registration (P = .01) as well as a degradation (defined as R < -1) when the rigid registration was compared with the novel deformable guidance information (P = .03). CONCLUSION This study provides evidence of the benefit of deformation correction in providing an accurate location for the liver for use in image-guided surgery systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound.

Soft-tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface-based metrics, and subsurface validation has largely been perfor...

متن کامل

Using an Android application to assess registration strategies in open hepatic procedures: a planning and simulation tool

Sparse surface digitization with an optically tracked stylus for use in an organ surface-based image-to-physical registration is an established approach for image-guided open liver surgery procedures. However, variability in sparse data collections during open hepatic procedures can produce disparity in registration alignments. In part, this variability arises from inconsistencies with the patt...

متن کامل

Validation of model-based deformation correction in image-guided liver surgery via tracked intraoperative ultrasound: preliminary method and results

Soft tissue deformation represents a significant error source in current surgical navigation systems used for open hepatic procedures. While numerous algorithms have been proposed to rectify the tissue deformation that is encountered during open liver surgery, clinical validation of the proposed methods has been limited to surface based metrics and sub-surface validation has largely been perfor...

متن کامل

The sparse data extrapolation problem: strategies for soft-tissue correction for image-guided liver surgery

The problem of extrapolating cost-effective relevant information from distinctly finite or sparse data, while balancing the competing goals between workflow and engineering design, and between application and accuracy is the ‘sparse data extrapolation problem’. Within the context of open abdominal image-guided liver surgery, one realization of this problem is compensating for non-rigid organ de...

متن کامل

Technical note: Nonrigid registration for laparoscopic liver surgery using sparse intraoperative data

Soft tissue deformation can be a major source of error for image-guided interventions. Deformations associated with laparoscopic liver surgery can be substantially different from those concomitant with open approaches due to intraoperative practices such as abdominal insufflation and variable degrees of mobilization from the supporting ligaments of the liver. This technical note outlines recent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Surgery

دوره 162 3  شماره 

صفحات  -

تاریخ انتشار 2017