Comment on "Comparison of ionization chambers of various volumes for IMRT absolute dose verification".
نویسندگان
چکیده
IMRT plans are usually verified by phantom measurements: dose distributions are measured using film and the absolute dose using an ionization chamber. The measured and calculated doses are compared and planned MUs are modified if necessary. To achieve a conformal dose distribution, IMRT fields are composed of small subfields, or "beamlets." The size of beamlets is on the order of 1 x 1 cm2. Therefore, small chambers with sensitive volumes < or = 0.1 cm3 are generally used for absolute dose verification. A dosimetry system consisting of an electrometer, an ion chamber, and connecting cables may exhibit charge leakage. Since chamber sensitivity is proportional to volume, the effect of leakage on the measured charge is relatively greater for small chambers. Furthermore, the charge contribution from beamlets located at significant distances from the point of measurement may be below the small chambers threshold and hence not detected. On the other hand, large (0.6 cm3) chambers used for the dosimetry of conventional external fields are quite sensitive. Since these chambers are long, the electron fluence through them may not be uniform ("temporal" uniformity may not exist in the chamber volume). However, the cumulative, or "spatial" fluence distribution (as indicated by calculated IMRT dose distribution) may become uniform at the chamber location when the delivery of all IMRT fields is completed. Under the condition of "spatial" fluence uniformity, the charge collected by the large chamber may accurately represent the absolute dose delivered by IMRT to the point of measurement. In this work, 0.6, 0.125, and 0.009 cm3 chambers were used for the absolute dose verification for tomographic and step-and-shoot IMRT plans. With the largest, 0.6 cm3 chamber, the measured dose was equal to calculated within 0.5%, when no leakage corrections were made. Without leakage corrections, the error of measurement with a 0.125 cm3 chamber was 2.6% (tomographic IMRT) and 1.5% (step-and-shoot IMRT). When doses measured by a 0.125 cm3 chamber were corrected for leakage, the difference between the calculated and measured doses reduced to 0.5%. Leakage corrected doses obtained with the 0.009 cm3 chamber were within 1.5%-1.7% of calculated doses. Without leakage corrections, the measurement error was 16% (tomographic IMRT) and 7% (step-and-shoot IMRT).
منابع مشابه
Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملCamera based EPID dosimetric verification of radiation treatments
Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context. Materials and Methods: In this study, ...
متن کاملA patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments.
The recalculation of 1 fraction from a patient treatment plan on a phantom and subsequent measurements have become the norms for measurement-based verification, which combines the quality assurance recommendations that deal with the treatment planning system and the beam delivery system. This type of evaluation has prompted attention to measurement equipment and techniques. Ionization chambers ...
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملCharacterization of cylindrical ionization chambers for patient specific IMRT QA
Proven conventional dosimetry techniques do not provide accuracy and precision in the measurement of inverse planned intensity modulated radiation therapy (IMRT) fields. Dynamic and step-and-shoot multileaf collimation (DMLC/SMLC) challenge current ionization chamber dosimetry practices. Ionization chamber performance in these fields is evaluated for three cylindrical chambers of varying volume...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 30 8 شماره
صفحات -
تاریخ انتشار 2003