BSLIM: Spectral Localization by Imaging With Explicit B0 Field Inhomogeneity Compensation
نویسندگان
چکیده
Magnetic resonance spectroscopy imaging (MRSI) is an attractive tool for medical imaging. However, its practical use is often limited by the intrinsic low spatial resolution and long acquisition time. Spectral localization by imaging (SLIM) has been proposed as a non-Fourier reconstruction algorithm that incorporates spatial a priori information about spectroscopically uniform compartments. Unfortunately, the influence of the magnetic field inhomogeneity--in particular, the susceptibility effects at tissues' boundaries--undermines the validity of the compartmental model. Therefore, we propose BSLIM as an extension of SLIM with field inhomogeneity compensation. A B0-field inhomogeneity map, which can be acquired rapidly and at high resolution, is used by the new algorithm as additional a priori information. We show that the proposed method is distinct from the generalized SLIM (GSLIM) framework. Experimental results of a two-compartment phantom demonstrate the feasibility of the method and the importance of inhomogeneity compensation.
منابع مشابه
FIELD INHOMOGENEITY COMPENSATION IN HIGH FIELD MAGNETIC RESONANCE IMAGING (MRI) by
FIELD INHOMOGENEITY COMPENSATION IN HIGH FIELD MAGNETIC RESONANCE IMAGING (MRI) Zhenghui Zhang, PhD University of Pittsburgh, 2006 This thesis concentrates on the reduction of field (both main field B0 and RF field B1) inhomogeneity in MRI, especially at high B0 field. B0 and B1 field inhomogeneity are major hindrances in high B0 field MRI applications. B1 inhomogeneity will lead to spatially v...
متن کاملQuantitative T(1)(ρ) imaging using phase cycling for B0 and B1 field inhomogeneity compensation.
T(1)(ρ) imaging is useful in a number of clinical applications. T(1)(ρ) preparation methods, however, are sensitive to non-uniformities of the B0 magnetic field and the B1 RF field. These common system imperfections can result in image artifacts and quantification errors in T(1)(ρ) imaging. We report on a phase-cycling method which can eliminate B1 RF inhomogeneity effects in T(1)(ρ) imaging. T...
متن کاملFour dimensional spectral-spatial fat saturation pulse design.
PURPOSE The conventional spectrally selective fat saturation pulse may perform poorly with inhomogeneous amplitude of static (polarizing) field (B0 ) and/or amplitude of (excitation) radiofrequency field (B1 ) fields. We propose a four dimensional spectral-spatial fat saturation pulse that is more robust to B0/B1 inhomogeneity and also shorter than the conventional fat saturation pulse. THEOR...
متن کاملA method for macroscopic B0 field inhomogeneity compensated SWI using 3D z-shim multi-echo GRE
Purpose Susceptibility weighted imaging (SWI) based on GRE provides enhancement of susceptibility difference which is useful for visualization of vein, micro-hemorrhage and iron deposition. However, GRE suffers from the macroscopic B0 inhomogeneity due to air/tissue boundary and this effect is shown as SNR loss both in magnitude and phase. Previously, 3D z-shim multi-echo GRE (mGRE) pulse seque...
متن کاملParallel Excitation: Making SENSE of High-Field Body MRI
MR imaging at high B0 field strength presents significant diagnostic opportunities derived from enhancements in SNR, spectral resolution and image contrast. However there are technical challenges that substantially hamper the practice of high-field MRI, including a major one that is related to the exploitation of the radio frequency EM field (B1 field and concomitant E field). As field strength...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on medical imaging
دوره 26 7 شماره
صفحات -
تاریخ انتشار 2007