ECG Artifact Removal from Surface EMG Using Adaptive filter Algorithm
نویسنده
چکیده
The electrocardiography (ECG) artifact corrupts the surface electromyography (sEMG) signals recorded from the trunk area We assessed the effectiveness of three methods used to remove the ECG. We compared the performance of bandpass filtering methods, the commonly used mathematical morphology operator (MMO) method and the Adaptive filter on both simulationed and real sEMG data. False positive and false negative errors increased with larger ECG to EMG ratios for all 3 methods. However, the Adaptive filter showed better performance as compared to bandpass filtering and the MMO particularly for low signal-to-artifact ratios of a lower computational load.
منابع مشابه
Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique
Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...
متن کاملCorrigendum to: “Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique†published in J Biomed Phys Eng 2014; 4(1):31-38
متن کامل
ECG Artifact Removal from Surface EMG Signal Using an Automated Method Based on Wavelet-ICA
This study aims at proposing an efficient method for automated electrocardiography (ECG) artifact removal from surface electromyography (EMG) signals recorded from upper trunk muscles. Wavelet transform is applied to the simulated data set of corrupted surface EMG signals to create multidimensional signal. Afterward, independent component analysis (ICA) is used to separate ECG artifact componen...
متن کاملDenoising of ECG Signals with Adaptive Filtering Algorithms & Patch Based Method
ECG signals have been proven a very versatile tool for detection of cardiovascular diseases. But during recording of these signals, the ECG data gets contaminated by various noise signals caused by power line interference, base line wander, electrode movement, muscle movement (EMG) etc. These noise signals are known as artifacts. These artifacts mislead the diagnosis of heart which is not desir...
متن کاملRemoval of Artifacts from ECG Signal Using RLS Based Adaptive Filter: A Review
The electrocardiogram (ECG) is used for diagnosis of heart diseases. In a few circumstances the recorded ECG signals are corrupted by various noise signals caused by power line interference, base line wander, electrode movement, muscular movement (EMG) etc. These noise signals are known as artifacts. These artifacts mislead the diagnosis of heart which is not desired. To avoid this problem caus...