High-resolution retinal imaging of cone-rod dystrophy.

نویسندگان

  • Jessica I Wolfing
  • Mina Chung
  • Joseph Carroll
  • Austin Roorda
  • David R Williams
چکیده

PURPOSE This study examines a patient with cone-rod dystrophy using high-resolution adaptive optics retinal imaging. Conventional ophthalmoscopes provide limited resolution due to their inability to overcome the eye's optical aberrations. In contrast, adaptive optics ophthalmoscopes correct these aberrations to provide noninvasive high-resolution views of the living retina. To date, adaptive optics ophthalmoscopy has been used mainly to examine the normal retina. Here we use adaptive optics ophthalmoscopy to image cone-rod dystrophy in vivo and compare these results with standard clinical tests. DESIGN Observational case report. METHODS High-resolution retinal images of a patient with cone-rod dystrophy were obtained with the University of Rochester adaptive optics flood-illuminated ophthalmoscope and the adaptive optics scanning laser ophthalmoscope located at the University of Houston and compared with standard clinical tests, including fundus photography, Goldmann visual fields, fluorescein angiography, optical coherence tomography, electroretinography, and multifocal electroretinography. MAIN OUTCOME MEASURES Direct measurement of cone density and diameter and comparison of adaptive optics images with standard clinical imaging and functional tests. RESULTS Adaptive optics images were acquired at multiple retinal locations throughout a clinically detected bull's-eye lesion. Within the atrophic regions, we observed large areas devoid of wave-guiding cones. In contrast, regions that appeared relatively spared by clinical examination contained a completely tiled cone mosaic. However, in these areas the cones were abnormally large, resulting in a 6.6-fold reduction from the normal peak cone density (patient peak density: 30 100 cones/mm2, normal peak density: 199 200 cones/mm2). Multifocal electroretinography confirmed a 5.5-fold reduction in amplitude of the central peak (10.8 nanovolts/degree2 vs. 59.8 nanovolts/degree2). CONCLUSIONS Adaptive optics ophthalmoscopy is a noninvasive technique to observe a patient's retinal pathology directly at a cellular level. It can provide a quantitative measurement of photoreceptor loss in retinal disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution in vivo imaging of the RPE mosaic in eyes with retinal disease.

PURPOSE To use high-resolution and contrast imaging techniques to reveal microscopic retinal structures, including individual retinal pigment epithelial (RPE) cells, in human eyes with inherited retinal disease. METHODS Adaptive optics scanning laser ophthalmoscopy (AOSLO) was used to image the macular region in patients with retinal degenerative diseases, including two patients with cone-rod...

متن کامل

Wide-field fundus autofluorescence abnormalities and visual function in patients with cone and cone-rod dystrophies.

PURPOSE To evaluate the clinical utility of wide-field fundus autofluorescence (FAF) in patients with cone dystrophy and cone-rod dystrophy. METHODS Sixteen patients with cone dystrophy (CD) and 41 patients with cone-rod dystrophy (CRD) were recruited at one institution. The right eye of each patient was included for analysis. We obtained wide-field FAF images using a ultra-widefield retinal ...

متن کامل

Phenotypic diversity in autosomal-dominant cone-rod dystrophy elucidated by adaptive optics retinal imaging

PURPOSE Several genes causing autosomal-dominant cone-rod dystrophy (AD-CRD) have been identified. However, the mechanisms by which genetic mutations lead to cellular loss in human disease remain poorly understood. Here we combine genotyping with high-resolution adaptive optics retinal imaging to elucidate the retinal phenotype at a cellular level in patients with AD-CRD harbouring a defect in ...

متن کامل

A pilot study of Fourier-domain optical coherence tomography of retinal dystrophy patients.

PURPOSE To characterize the macular anatomy of retinal dystrophy eyes using high-speed, high-resolution, Fourier-domain optical coherence tomography (FD-OCT). DESIGN Case-control study. METHODS Retinal dystrophy patients and normal age- and gender-matched controls underwent FD-OCT imaging using the RTVue (Optovue Inc., Fremont, California, USA). Vertical and horizontal 8-mm scans of 1024 li...

متن کامل

Rod and cone photoreceptor function in patients with cone dystrophy.

PURPOSE To determine the extent of rod and cone photoreceptor dysfunction in patients with cone dystrophy using psychophysical and electrophysiological tests. METHODS Ten patients with cone dystrophy participated. Rod and cone system psychophysical thresholds were measured as a function of retinal eccentricity. Bright-flash full-field electroretinograms were obtained under dark-adapted (rod-m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 113 6  شماره 

صفحات  -

تاریخ انتشار 2006