چکیده
Modern molecular electronic transfer (MET) angular motion sensors combine high technical characteristics with low cost. Self-noise is one of the key characteristics which determine applications for MET sensors. However, until the present there has not been a model describing the sensor noise in the complete operating frequency range. The present work reports the results of an experimental study of the self-noise level of such sensors in the frequency range of 0.01-200 Hz. Based on the experimental data, a theoretical model is developed. According to the model, self-noise is conditioned by thermal hydrodynamic fluctuations of the operating fluid flow in the frequency range of 0.01-2 Hz. At the frequency range of 2-100 Hz, the noise power spectral density has a specific inversely proportional dependence of the power spectral density on the frequency that could be attributed to convective processes. In the high frequency range of 100-200 Hz, the noise is conditioned by the voltage noise of the electronics module input stage operational amplifiers and is heavily reliant to the sensor electrical impedance. The presented results allow a deeper understanding of the molecular electronic sensor noise nature to suggest the ways to reduce it.
منابع مشابه
Low-noise Linear and Angular Motion Sensors for Vibration Monitoring
* The presented researches was supported by Russian Ministry of Science and Education, project ID RFMEFI57814X0013. Abstract— This article reviews on the development of a new category motion sensors for vibration monitoring including linear and angular accelerometers based on molecular electronic transducer (MET) technology. This technology utilizes liquid not only as an inertial mass but also ...
متن کاملMolecular Electric Transducers as Motion Sensors: A Review
This article reviews the development of a new category of motion sensors including linear and angular accelerometers and seismometers based on molecular electronic transducer (MET) technology. This technology utilizes a liquid not only as an inertial mass, but also as one of the main elements in the conversion of mechanical motion into electric current. The amplification process is similar to t...
متن کاملCustom EMAT Instrumentation: Correlation Receiver and Flaw Detector
An updated NDE instrument has been designed that is compatible with existing water path pulse echo instruments. The use of modern integrated circuit video amplifiers and broad band signal processing in the receiver permits improvements in signal-to-noise and band width to be simultaneously achieved. Additional circuits provide a variable depth--varialbe width processing gate, a peak detector fo...
متن کاملAngular Molecular–Electronic Sensor with Negative Magnetohydrodynamic Feedback
A high-precision angular accelerometer based on molecular-electronic transfer (MET) technology with a high dynamic range and a low level of self-noise has been developed. Its difference from the analogues is in the use of liquid (electrolyte) as the inertial mass and the use of negative feedback based on the magnetohydrodynamic effect. This article reports on the development of the angular mole...
متن کاملLong Wave Ultrasonic Characterization of Inclusions in Silicon Nitride
The size and material content of Fe and Si inclusions in Si 3N4 have been measured by means of pulseecho scattering of elastic waves in the frequency range 5 to 100 MHz. The inclusions were of 100 lJm and 400 llm nominal diameters and were located 3 mm deep in the Si 3N4. The electronic noise was reduced by signal averaging and, in some cases, the noise due to grain scattering was reduced by av...