Polypropylene and polypropylene/polyglecaprone (Ultrapro®) meshes in the repair of incisional hernia in rats.

نویسندگان

  • Edivaldo Massazo Utiyama
  • Maria Beatriz Sartor de Faria Rosa
  • Marina de Paula Andres
  • Jocielle Santos de Miranda
  • Sérgio Henrique Bastos Damous
  • Cláudio Augusto Vianna Birolini
  • Luciana Lamarão Damous
  • Edna Frasson de Souza Montero
چکیده

PURPOSE To compare the inflammatory response of three different meshes on abdominal hernia repair in an experimental model of incisional hernia. METHODS Median fascial incision and skin synthesis was performed on 30 Wistar rats. After 21 days, abdominal hernia developed was corrected as follows: 1) No mesh; 2) Polypropylene mesh; and, 3) Ultrapro(r) mesh. After 21 days, the mesh and surrounding tissue were submitted to macroscopic (presence of adhesions, mesh retraction), microscopic analysis to identify and quantify the inflammatory and fibrotic response using a score based on a predefined scale of 0-3 degrees, evaluating infiltration of macrophages, giant cells, neutrophils and lymphocytes. RESULTS No significant difference was seen among groups in adherences, fibrosis, giant cells, macrophages, neutrophils or lymphocytes (p>0.05). Mesh shrinkage was observed in all groups, but also no difference was observed between polypropylene and Ultrapro mesh (7.0±9.9 vs. 7.4±10.1, respectively, p=0.967). Post-operatory complications included fistula, abscess, dehiscence, serohematic collection and reherniation, but with no difference among groups (p=0.363). CONCLUSION There is no difference between polypropylene (high-density) and Ultrapro(r) (low-density) meshes at 21 days after surgery in extraperitoneal use in rats, comparing inflammatory response, mesh shortening, adhesions or complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tensiometric Analysis of Meshes Used in Abdominal Ventral Wall Defects in Rats

BACKGROUND Among the various strategies to avoid exaggerated foreign body reaction in the treatment of hernias is the limitation of the amount of polypropylene or the use of absorbable material. AIM To evaluate the healing of defects in the abdominal wall of rats, comparing microporous polypropylene, macroporous polypropylene and polypropylene/polyglecaprone at the 30º, 60º and 120º postopera...

متن کامل

Effects of ethylene oxide resterilization and in-vitro degradation on mechanical properties of partially absorbable composite hernia meshes.

BACKGROUND AND AIM Prosthetic mesh repair for abdominal wall hernias is widely used because of its technical simplicity and low hernia recurrence rates. The most commonly used material is pure polypropylene mesh, although newer composite materials are recommended by some centers due to their advantages.However, these meshes are more expensive than pure polypropylene meshes. Resterilization of a...

متن کامل

Effects of Ethylene Oxide Resterilisation and In-vitro Degradation on Mechanical Properties of Partially Absorbable Composite Hernia Meshes.

BACKGROUND Prosthetic mesh repair for abdominal wall hernias is widely used because of its technical simplicity and low hernia recurrence rates. The most commonly used material is pure polypropylene mesh, however newer composite materials are recommended by some centers because of their advantages. However, these meshes are more expensive than pure polypropylene meshes. Resterilisation of a pur...

متن کامل

Stem Cells Hematopoietic Niches and Inflammatory Response to Different Synthetic Prosthesis Implanted in Rat with Incisional Hernias

BACKGROUND Extramedullary hematopoiesis depends on complex pathophysiological mechanisms linked to hematopoietic stem cells and the proteins considered mediators of the inflammation. The identification of hematopoietic cells outside bone marrow in the adult is an occurrence that can occasionally follows the inflammatory response, was considered a secondary occurrence, but current biomolecular s...

متن کامل

Significant improvement of biocompatibility of polypropylene mesh for incisional hernia repair by using poly-ε-caprolactone nanofibers functionalized with thrombocyte-rich solution

Incisional hernia is the most common postoperative complication, affecting up to 20% of patients after abdominal surgery. Insertion of a synthetic surgical mesh has become the standard of care in ventral hernia repair. However, the implementation of a mesh does not reduce the risk of recurrence and the onset of hernia recurrence is only delayed by 2-3 years. Nowadays, more than 100 surgical mes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta cirurgica brasileira

دوره 30 6  شماره 

صفحات  -

تاریخ انتشار 2015