A single-suture technique for placement of the ganciclovir implant.

نویسندگان

  • B E Jones
  • D V Weinberg
چکیده

The ganciclovir implant is a surgically implanted sustained-release drug delivery system used for the treatment of cytomegalovirus retinitis. The device is suspended in the vitreous cavity through a pars plana incision. Previous reports of the surgical procedure have described securing the implant on 1 suture, tied with an external knot. The ends of this suture were left long to avoid sharp ends eroding through the conjunctiva. The wound was then closed with 1 or more additional sutures, with the ends tied and cut short. We describe a technique whereby the wound is closed and the implant secured with a single running suture. The advantages of this technique include efficiency and elimination of exposed knots. We have observed no complications attributable to this technique.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Suture loop to aid in ganciclovir implant removal.

BACKGROUND The ganciclovir implant (Vitrasert; Bausch & Lomb Inc, Claremont, Calif) has been a useful device in the management of cytomegalovirus retinitis. Seven months after placement, implant exchange is often considered. However, removal may be difficult and may result in vitreous hemorrhage or intraocular dislocation. OBJECTIVE To describe a suture loop attached to the implant strut and ...

متن کامل

Method for the placement of palatal implants.

PURPOSE Palatal implants have been used in the last 2 decades to eliminate headgear wear and to establish stationary anchorage. The aim of this investigation was to establish a method and easy protocol for palatal implant placement. MATERIALS AND METHODS The study comprised 8 male and 15 female patients each having a 4.5 x 8-mm stepped screw titanium implant placed in the palatal region for o...

متن کامل

A Two-step Method for the Preparation of Implant Recipient Site in Severe Atrophic Maxilla: A Case Report of the Alveolar Ridge Split Technique Followed by Bone Expansion

Augmentation of deficient and atrophic alveolar ridges is an important aspect of dental implant therapy with the goal of providing a functional restoration in harmony with adjacent natural dentition. Bone splitting technique is considered a distinguished augmentation method for treatment of deficient alveolar ridges. According to this procedure, the compromised alveolar ridge is opened from the...

متن کامل

Using Absorbable Gelatin Sponge to Facilitate Sinus Membrane Elevation during Open Sinus Lift: Technical Notes and Case Series

Ridge atrophy accompanied by the pneumatization of maxillary sinus in the maxillary posterior region may lead to inadequate bone height, thereby precluding implant placement. Therefore, it may be mandatory to perform a sinus membrane elevation procedure and augmentation in the bone. The present study aimed to introduce a novel modification method for sinus floor elevation using a gelatin sponge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 118 4  شماره 

صفحات  -

تاریخ انتشار 2000