Evaluation of three different dental implants in ligature-induced peri-implantitis in the beagle dog. Part I. Clinical evaluation.
نویسندگان
چکیده
The purpose of this study was to clinically evaluate experimental peri-implant breakdown. Hydroxyapatite-coated, titanium plasma-sprayed, and machined titanium-alloy surfaces were investigated. Eighty-four implants were placed in 14 beagle dogs. Pocket probing depths and clinical attachment level and mobility measurements were made. Dogs were sacrificed at 3 and 6 months. All experimental implants showed a significant loss in clinical attachment level (P < .05). Increased pocket probing depths for experimental implants occurred during the first 2 months, after which a plateau was reached. At the 3- and 6-month evaluation, pocket probing depths at experimental implants were significantly increased (P < .05). No differences among the three implant types were noted for clinical attachment levels and pocket probing depths. In general, greater mobility was found with the titanium-alloy implants than with hydroxyapatite-coated and titanium plasma-sprayed implants (P < .025). In addition, mobility measurements were significantly greater for experimental titanium-alloy implants during the first 3 months (P < .05). Clinical attachment level measurements were most sensitive to peri-implant status. All implants were equally susceptible to ligature-induced peri-implant breakdown. Consequently, meticulous oral hygiene and regular maintenance care are prerequisites for successful implantology.
منابع مشابه
Evaluation of three different dental implants in ligature-induced peri-implantitis in the beagle dog. Part II. Histology and microbiology.
The purpose of this study was to evaluate experimental peri-implant breakdown microbiologically, radiographically and histologically. Hydroxyapatite-coated, titanium plasma-sprayed, and titanium alloy surfaces were investigated. Eighty-four implants were placed in 14 beagle dogs. Standardized radiographs and microbiologic samples (DNA) were obtained. Dogs were sacrificed at 3 and 6 months. Unde...
متن کاملEvaluation in a Dog Model of Three Antimicrobial Glassy Coatings: Prevention of Bone Loss around Implants and Microbial Assessments.
OBJECTIVES The aim of the present study is to evaluate, in a ligature-induced peri-implantitis model, the efficacy of three antimicrobial glassy coatings in the prevention of biofilm formation, intrasulcular bacterial growth and the resulting peri-implant bone loss. METHODS Mandibular premolars were bilaterally extracted from five beagle dogs. Four dental implants were inserted on each hemiar...
متن کاملPeri-implantitis Induced by Stainless Steel Ligature in Beagle Dogs.
The purpose of this study was to develop a new method for a peri-implantitis model in beagle dogs in which a stainless steel ligature (SSL) was used independently. A total of 36 Straumann dental implants were placed in six beagle dogs 1 month after all mandibular premolars were extracted. After 3 months, SSLs were placed in a submarginal position on the implants to induce peri-implantitis and w...
متن کاملEffect of implant placement depth on the peri-implant bone defect configurations in ligature-induced peri-implantitis: An experimental study in dogs
BACKGROUND The subcrestal placement of implant platform has been considered a key factor in the preservation of crestal bone, but the influence of implant placement depth on bone remodeling combined with peri-implantitis is not fully understood. The aim of this study was to assess the effect of the crestal or subcrestal placement of implants on peri-implant bone defects of ligature-induced peri...
متن کاملExperimental peri-implant tissue breakdown around different dental implant surfaces: clinical and radiographic evaluation in dogs.
PURPOSE Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. MATERIALS AND METHODS In 6 male mongrel dogs, a total of 36 dental implants with different surfaces (9 titanium plasma-sprayed, 9 hydroxyapatite-coated, 9 acid-etched, and 9 commercially pure titanium) were placed 3 months after mandibular ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 12 5 شماره
صفحات -