Testing flow-through air samplers for use in near-field vapour drift studies by measuring pyrimethanil in air after spraying.

نویسندگان

  • Trudyanne S Geoghegan
  • Kimberly J Hageman
  • Andrew J Hewitt
چکیده

Pesticide volatilisation and subsequent vapour drift reduce a pesticide's efficiency and contribute to environmental contamination. High-volume air samplers (HVSs) are often used to measure pesticide concentrations in air but these samplers are expensive to purchase and require network electricity, limiting the number and type of sites where they can be deployed. The flow-through sampler (FTS) presents an opportunity to overcome these limitations. The FTS is a wind-driven passive sampler that has been developed to quantify organic contaminants in remote ecosystems. FTSs differ from other passive samplers in that they turn into the wind and use the wind to draw air through the sampling media. The main objective of this work was to evaluate the FTS in a near-field pesticide vapour drift study by comparing the concentrations of pyrimethanil in air measured using one HVS and three FTSs placed in the same location. Pyrimethanil was sprayed onto a vineyard as part of normal pest management procedures. Air samples were collected every eight hours for 48 h. The volume of air sampled by the FTSs was calculated using the measured relationship between ambient wind speed and the wind speed inside the sampler as determined with a separate wind tunnel study. The FTSs sampled 1.7 to 40.6 m(3) of air during each 8 h sampling period, depending on wind speed, whereas the mean volume sampled by the HVS was 128.7 m(3). Mean pyrimethanil concentrations ranged from 0.4 to 3.2 μg m(-3) of air. Inter-sampler reproducibility, as represented by percent relative standard deviation, for the three FTSs was ∼20%. The largest difference in FTS-derived versus HVS-derived pyrimethanil concentrations occurred during the lowest wind-speed period. During this period, it is likely that the FTS predominately acted like a traditional diffusion-based passive sampler. As indicated by both types of sampler, pyrimethanil concentrations in air changed by a factor of ∼2 during the two days after spaying. This work shows that the FTS has good potential for use in near-field vapour drift studies and that FTS technology could make multi-sampler experimental designs more feasible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Characteristics of Personal Samplers in Still and Moving Air

Personal samplers or in general blunt body samplers are widely used in occupational hygiene for collecting air contaminants in the work environments. This work is part of an ongoing research into the performance evaluation of personal samplers, particularly in terms of their aerodynamic properties. Velocity profiles have been measured around and within typical cylindrical sampling devices, ...

متن کامل

Use of a Terrestrial LIDAR Sensor for Drift Detection in Vineyard Spraying

The use of a scanning Light Detection and Ranging (LIDAR) system to characterize drift during pesticide application is described. The LIDAR system is compared with an ad hoc test bench used to quantify the amount of spray liquid moving beyond the canopy. Two sprayers were used during the field test; a conventional mist blower at two air flow rates (27,507 and 34,959 m3·h(-1)) equipped with two ...

متن کامل

Flow rate measurement in modern ambient air samplers – how accurate ?

New generation ambient air samplers operate at much lower sampling flow rates than do their “high volume” predecessors, namely 16.7 liters/minute. When these new air samplers emerged several years ago there were limited tools available with which to assess and calibrate their operating flow rate. In 1996 a flow meter specifically designed for these new air samplers came available, known as the ...

متن کامل

Turbulent Events and Gas-Side Mass Transfer Coefficients in a Wavy Air-Water Stratified Flow

Turbulence structure on the gas side of a wavy stratified flow was experimentally investigated in a near horizontal 18.7 cm (H) 10 cm (W) 5.5m (L) rectangular duct.By applying the Variable Interval Time Averaging (VITA) technique to the hot wire anemometer measurements frequency of occurrence of turbulent events were detected near the air-water interface. Experimental results showed that fr...

متن کامل

OFF - TARGET DRIFT OF MCPA : “ REAL - TIME ” AIR SAMPLING bY

. The drift of MCPA downwind of an aerial application was measured using short air sampling intervals in an attempt to estimate “real-time” concentrations. Prior drift studies examined deposition patterns or measured air concentrations downwind of pesticide applications using long sampling intervals (1 to 24 hours). This preliminary study was designed to determine: 1) the Eeasibility of “real-t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science. Processes & impacts

دوره 16 3  شماره 

صفحات  -

تاریخ انتشار 2014