Real-time imaging required for optimal echocardiographic assessment of aortic valve calcification
نویسندگان
چکیده
INTRODUCTION Aortic valve calcification (AVC), even without haemodynamic significance, may be prognostically import as an expression of generalized atherosclerosis, but techniques for echocardiographic assessment are essentially unexplored. METHODS Two-dimensional (2D) echocardiographic recordings (Philips IE33) of the aortic valve in short-axis and long-axis views were performed in 185 consecutive patients within 1 week before surgery for aortic stenosis (n = 109, AS), aortic regurgitation (n = 61, AR), their combination (n = 8) or dilation of the ascending aorta (n = 7). The grey scale mean (GSMn) of the aortic valve in an end-diastolic short-axis still frame was measured. The same frame was scored visually 1-5 as indicating that the aortic valve was normal, thick, or had mild, moderate or severe calcification. The visual echodensity of each leaflet was determined real time applying the same 5-grade scoring system for each leaflet, and the average for the whole valve was calculated. Finally, a similar calcification score for the whole valve based on inspection and palpation by the surgeon was noted. RESULTS Visual assessment of real-time images using the proposed scoring system showed better correlation with the surgical evaluation of the degree of valve calcification (r = 0·83, P<0·001) compared to evaluation of stop frames by visual assessment (r = 0·66, P< 0·001) or the GSMn score (r = 0·64, P< 0·001). High inter- and intra-observer correlations were observed for real-time visual score (both intraclass correlation coefficient = 0·93). CONCLUSION Real-time evaluation of the level of AVC is superior to using stop frames assessed either visually or by dedicated computer grey scale measurement software.
منابع مشابه
Doppler echocardiographic findings in tissue engineered aortic valve in a sheep model
Background: Heart valve diseases are considered a common disease in human and animals, and valve replacement is an option for treatment of valvular diseases. Objectives: In this study efficacy of a tissue engineered valve in thoracic aorta was evaluated with transthoracic echocardiography. Methods: This study was undertaken on 6 male sheep. Echocardiography was performed on all sheep 24 hours b...
متن کاملCARDIOVASCULAR MEDICINE Three dimensional volume quantification of aortic valve calcification using multislice computed tomography
Objective: To assess a new multislice computed tomography (CT) technique for three dimensional quantification of aortic valve calcification volume (3D AVCV) and to study the relation between stenosis and calcification of the aortic valve. Methods: 50 patients with echocardiographic calcification of the aortic valve underwent two separate ECG triggered multislice CT for quantification of 3D AVCV...
متن کاملThree dimensional volume quantification of aortic valve calcification using multislice computed tomography.
OBJECTIVE To assess a new multislice computed tomography (CT) technique for three dimensional quantification of aortic valve calcification volume (3D AVCV) and to study the relation between stenosis and calcification of the aortic valve. METHODS 50 patients with echocardiographic calcification of the aortic valve underwent two separate ECG triggered multislice CT for quantification of 3D AVCV...
متن کاملEvaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography.
BACKGROUND Electron-beam computed tomography (EBCT) is used to measure coronary calcification but not for aortic valve calcification (AVC). Its accuracy, association with aortic stenosis (AS) severity, and diagnostic and prognostic value with respect to AVC are unknown. METHODS AND RESULTS In 30 explanted aortic valves, the AVC score by EBCT (1125+/-1294 Agatston units [AU]) showed a strong l...
متن کاملEchocardiographic integrated backscatter for the differentiation between aortic valve calcification and valvular myxoid degeneration in rats.
AIMS Calcification is an independent predictor of mortality in aortic valve (AV) stenosis. Echocardiographic calibrated integrated backscatter (cIB) is a promising parameter for quantifying AV calcification. However, the ability of cIB to differentiate between calcification and valvular thickening has been questioned. Therefore, we aimed to use cIB to study AV calcification compared with non-ca...
متن کامل