Interventional MRI: tapering improves the distal sensitivity of the loopless antenna.
نویسندگان
چکیده
The "loopless antenna" is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or "whip". A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. It is shown here that tapered insulation dramatically improves the distal sensitivity of the loopless antenna by pushing the current sensitivity toward the tip. The absolute signal-to-noise ratio is numerically computed by the electromagnetic method-of-moments for three resonant 3-T antennae with no insulation, uniform insulation, and with linearly tapered insulation. The analysis shows that tapered insulation provides an approximately 400% increase in signal-to-noise ratio in trans-axial planes 1 cm from the tip and a 16-fold increase in the sensitive area as compared to an equivalent, uniformly insulated antenna. These findings are directly confirmed by phantom experiments and by MRI of an aorta specimen. The results demonstrate that numerical electromagnetic signal-to-noise ratio analysis can accurately predict the loopless detector's signal-to-noise ratio and play a central role in optimizing its design. The manifold improvement in distal signal-to-noise ratio afforded by redistributing the insulation should improve the loopless antenna's utility for interventional MRI.
منابع مشابه
Axial Corrugated Horn Antenna with Elliptical Tapering Function
An axially corrugated horn antenna with an elliptically shaped taper is proposed for satellite communication applications. This structure is a good candidate for the feed of reflectors and also for improving the electrical properties of reflector antennas. A tapering method is used to justify the horizontal location of the corrugation profile which improves the electrical performance of the pre...
متن کاملWhole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes
BACKGROUND Catheter visualization and tracking remains a challenge in interventional MR.Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "a...
متن کاملIn-stent lumen visualization using intravascular MRI and a bSSFP sequence
Introduction Performing magnetic resonance imaging inside metallic vascular stents still represents a major challenge in many cases. Metallic stents are known to hinder visualization of the inner lumen as a result of both susceptibility artefacts and radiofrequency shielding effects [1]. Proposed solutions to the radiofrequency shielding effects include the use of sequences with an increased fl...
متن کاملIntravascular extended sensitivity (IVES) MRI antennas.
The design and application of an intravascular extended sensitivity (IVES) MRI antenna is described. The device is a loopless antenna design that incorporates both an insulating, dielectric coating and a winding of the antenna whip into a helical shape. Because this antenna produces a broad region of high SNR and also allows for imaging near the tip of the device, it is useful for imaging long,...
متن کاملA New Intravascular Loopless Monopole Antenna (ILMA) for MR Imaging
In recent years, intravascular MR coil, which utilizes a special coil placed neighboring to the target artery, has been proposed to improve the local signal-to-noise ratio (SNR) and spatial resolution of vessel wall images. Especially the intravascular coil has identified its advantage in detecting atherosclerotic plaques [1]. At present, there are two types of intravascular MRI receivers: loop...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 63 3 شماره
صفحات -
تاریخ انتشار 2010