Anger-induced T-wave alternans predicts future ventricular arrhythmias in patients with implantable cardioverter-defibrillators.
نویسندگان
چکیده
OBJECTIVES This study sought to determine whether T-wave alternans (TWA) induced by anger in a laboratory setting predicts future ventricular arrhythmias in patients with implantable cardioverter-defibrillators (ICDs). BACKGROUND Anger can precipitate spontaneous ventricular tachycardia/ventricular fibrillation and induce TWA. Whether anger-induced TWA predicts future arrhythmias is unknown. METHODS Sixty-two patients with ICDs underwent ambulatory electrocardiography during a mental stress protocol, 3 months after the ICD was implanted. T-wave alternans was analyzed using time-domain methods. After a > or =1 year follow-up, ICD stored data was reviewed to determine incidence of ICD-terminated ventricular tachycardia/ventricular fibrillation. RESULTS Patients with ICD-terminated arrhythmias during follow-up (n = 10) had higher TWA induced by anger, 13.2 microV (interquartile range [IQR] 9.3 to 16 microV), compared with those patients without future ventricular arrhythmias, 9.3 microV (IQR 7.5 to 11.5 microV, p < 0.01). Patients in the highest quartile of anger-induced TWA (>11.9 microV, n = 15) were more likely to experience arrhythmias by 1 year than those in the lower quartiles (33% vs. 4%) and during extended follow-up (40% vs. 9%, p < 0.01 for both). In multivariable regression controlling for ejection fraction, prior clinical arrhythmia, and wide QRS, anger-induced TWA remained a significant predictor of arrhythmia, with likelihood in the top quartile 10.8 times that of other patients (95% confidence interval: 1.6 to 113, p < 0.05). CONCLUSIONS Anger-induced TWA predicts future ventricular arrhythmias in patients with ICDs, suggesting that emotion-induced repolarization instability may be 1 mechanism linking stress and sudden death. Whether there is a clinical role for anger-induced TWA testing requires further study.
منابع مشابه
Effects of acute mental stress and exercise on T-wave alternans in patients with implantable cardioverter defibrillators and controls.
BACKGROUND Malignant cardiac arrhythmias can be triggered by exercise and by mental stress in vulnerable patients. Exercise-induced T-wave alternans (TWA) is an established marker of cardiac electrical instability. However, the effects of acute mental stress on TWA have not been investigated as a vulnerability marker in humans. METHODS AND RESULTS TWA responses to mental stress (anger recall ...
متن کاملApplication of microvolt T-wave alternans testing in scheduling implantable cardioverter-defibrillator placement for the primary prevention of sudden cardiac death in patients with left ventricular dysfunction.
BACKGROUND Patients with left ventricular ejection fraction (LVEF) ≤ 35% are eligible for implantable cardioverter-defibrillator (ICD) placement for the primary prevention of sudden cardiac death (SCD). This recommendation results in continuously growing waiting lists of patients who have been qualified for and are awaiting the procedure. Whiled reduced LVEF is a feature shared by all the patie...
متن کاملNoninvasive arrhythmia risk stratification in idiopathic dilated cardiomyopathy: results of the Marburg Cardiomyopathy Study.
BACKGROUND Arrhythmia risk stratification with regard to prophylactic implantable cardioverter-defibrillator therapy is a completely unsolved issue in idiopathic dilated cardiomyopathy (IDC). METHODS AND RESULTS Arrhythmia risk stratification was performed prospectively in 343 patients with IDC, including analysis of left ventricular (LV) ejection fraction and size by echocardiography, signal...
متن کاملArrhythmia/Electrophysiology Intracardiac Electrogram T-Wave Alternans/Variability Increases Before Spontaneous Ventricular Tachyarrhythmias in Implantable Cardioverter-Defibrillator Patients A Prospective, Multi-Center Study
Background—T-wave alternans (TWA) increases before ventricular tachycardia (VT) or fibrillation (VF), suggesting that it may warn of VT/VF in implantable cardioverter-defibrillator patients. Recently, we described a method for measuring alternans and nonalternans variability (TWA/V) from electrograms (EGMs) stored in implantable cardioverterdefibrillators before VT/VF. The goal of this prospect...
متن کاملImmediate ventricular tachycardia after abnormal microvolt T-wave alternans.
Microvolt T-wave alternans (MTWA) is a promising non-invasive method of evaluating repolarization abnormalities. Its presence is strongly related to the occurrence of malignant ventricular tachyarrhythmias and is therefore regarded as a risk marker for sudden cardiac death. Most recent studies have described the usefulness of MTWA in selecting patients who may benefit from a cardioverter-defibr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 53 9 شماره
صفحات -
تاریخ انتشار 2009